Fix bug where if we have a non-PD aware charger, we constantly send
host events to notify EC of an input current limit change. This was
unintentionally broken when adding code to constantly monitor the
CC line pull-up strength and adjust the current limit accordingly.
BUG=none
BRANCH=samus
TEST=plug in a non-PD aware charger and make sure it sets the correct
input current limit and that it is not constantly sending host events
that the limit has changed.
Change-Id: I7d835769ebc768043a9a46f50721987dce0384f5
Signed-off-by: Alec Berg <alecaberg@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/235414
Reviewed-by: Shawn Nematbakhsh <shawnn@chromium.org>