Set input current limit based on the max current from the PD negotiation. For samus, this information is passed to the EC as a host command. For ryu, the max current is set directly following a negotiation. CONFIG_CHARGER_INPUT_CURRENT is now just the default limit, but after a successful PD negotiation, the limit can be raised. Note, for now the input current limit for samus is set to 2/3 of the value negotiated for. This is due to hardware problems measuring input current on p2b boards. BUG=chrome-os-partner:28532, chrome-os-partner:24461 BRANCH=none TEST=tested on a samus. Verified input current limit using "charger" console command from EC. Input current limit after a reboot is 512. When zinger is plugged in, it jumps to the appropriate value (currently 1280mA), and when the negotiation is changed using the "pd 0 dev 5" command on the PD console, the input current limit is adjusted to match (2000mA). Change-Id: Iab9186a0f9814655e3240217a9baf4a38f15f84d Signed-off-by: Alec Berg <alecaberg@chromium.org> Reviewed-on: https://chromium-review.googlesource.com/211023 Reviewed-by: Vincent Palatin <vpalatin@chromium.org>
79 lines
1.9 KiB
C
79 lines
1.9 KiB
C
/* Copyright (c) 2014 The Chromium OS Authors. All rights reserved.
|
|
* Use of this source code is governed by a BSD-style license that can be
|
|
* found in the LICENSE file.
|
|
*/
|
|
|
|
/* Host command module for PD MCU */
|
|
|
|
#include "charge_state.h"
|
|
#include "common.h"
|
|
#include "console.h"
|
|
#include "host_command.h"
|
|
#include "task.h"
|
|
#include "timer.h"
|
|
#include "util.h"
|
|
|
|
#define CPRINTS(format, args...) cprints(CC_PD_HOST_CMD, format, ## args)
|
|
|
|
#define TASK_EVENT_EXCHANGE_PD_STATUS TASK_EVENT_CUSTOM(1)
|
|
|
|
void host_command_pd_send_status(void)
|
|
{
|
|
task_set_event(TASK_ID_PDCMD, TASK_EVENT_EXCHANGE_PD_STATUS, 0);
|
|
}
|
|
|
|
static void pd_exchange_status(void)
|
|
{
|
|
struct ec_params_pd_status ec_status;
|
|
struct ec_response_pd_status pd_status;
|
|
int rv = 0, tries = 0;
|
|
|
|
/* Send battery state of charge */
|
|
if (charge_get_flags() & CHARGE_FLAG_BATT_RESPONSIVE)
|
|
ec_status.batt_soc = charge_get_percent();
|
|
else
|
|
ec_status.batt_soc = -1;
|
|
|
|
/* Try 3 times to get the PD MCU status. */
|
|
while (tries++ < 3) {
|
|
rv = pd_host_command(EC_CMD_PD_EXCHANGE_STATUS, 0, &ec_status,
|
|
sizeof(struct ec_params_pd_status), &pd_status,
|
|
sizeof(struct ec_response_pd_status));
|
|
if (rv >= 0)
|
|
break;
|
|
task_wait_event(500*MSEC);
|
|
}
|
|
|
|
if (rv < 0) {
|
|
CPRINTS("Host command to PD MCU failed");
|
|
return;
|
|
}
|
|
|
|
/* Set input current limit */
|
|
#ifdef BOARD_SAMUS
|
|
/*
|
|
* TODO(crosbug.com/p/28532): Remove this workaround for Samus p2b
|
|
* boards which cannot correctly limit input current.
|
|
*/
|
|
pd_status.curr_lim_ma = pd_status.curr_lim_ma * 2 / 3;
|
|
#endif
|
|
rv = charger_set_input_current(MAX(pd_status.curr_lim_ma,
|
|
CONFIG_CHARGER_INPUT_CURRENT));
|
|
if (rv < 0)
|
|
CPRINTS("Failed to set input current limit from PD MCU");
|
|
}
|
|
|
|
void pd_command_task(void)
|
|
{
|
|
|
|
while (1) {
|
|
/* Wait for the next command event */
|
|
int evt = task_wait_event(-1);
|
|
|
|
/* Process event to send status to PD */
|
|
if (evt & TASK_EVENT_EXCHANGE_PD_STATUS)
|
|
pd_exchange_status();
|
|
}
|
|
}
|
|
|