Bill Richardson 80c635ecab Add 'fanduty' command both EC console and ectool.
This forces the fan PWM duty cycle to a fixed percentage (0-100). It's only
used for airflow testing.

BUG=chrome-os-partner:10747
TEST=manual

Using this ectool, try

  ectool fanduty 0
  ectool pwmgetfanrpm
  ectool fanduty 50
  ectool pwmgetfanrpm
  ectool fanduty 100
  ectool pwmgetfanrpm

You should see (and hear) the fan speed up.  If you have an EC console, you
can run

  faninfo

and it should show that the 'Target:' is unrelated to the 'Actual:' value.

Change-Id: Iac332fb3ba63f96726cf7f64061b3ce22d2e76fd
Signed-off-by: Bill Richardson <wfrichar@chromium.org>
Reviewed-on: https://gerrit.chromium.org/gerrit/25965
Reviewed-by: Randall Spangler <rspangler@chromium.org>
2012-06-22 15:56:57 -07:00
..