Vincent Palatin 1f7961e693 ryu: workaround MAX77620 shutdown issue
When shutting down the MAX77620 PMIC by asseting its SHDN pin, the
EN_PP3300 output of the PMIC (GPIO3) is not going off keeping the PP3300
rail up. Workaround that issue by removing the pull-up on EN_PP3300 when
we assert SHDN.

Signed-off-by: Vincent Palatin <vpalatin@chromium.org>

BRANCH=none
BUG=chrome-os-partner:38689
TEST=on a P5 board, type "apshutdown" and see the power state machine
going to S5, type "powerbtn" and see it going back to S0.

Change-Id: I0e5fba6da118d931b07fff58088604ee00a6bcdd
Reviewed-on: https://chromium-review.googlesource.com/263958
Trybot-Ready: Vincent Palatin <vpalatin@chromium.org>
Tested-by: Vincent Palatin <vpalatin@chromium.org>
Reviewed-by: Alec Berg <alecaberg@chromium.org>
Commit-Queue: Vincent Palatin <vpalatin@chromium.org>