This allows the AP to shut down cleanly. If it doesn't shut down in
that time period, the EC will forcibly shut it down.
BUG=chrome-os-partner:17124
BRANCH=link
TEST=manual
1. With system off,
- battfake 2 -> EC hibernates immediately
2. With system on,
- battfake 2 -> battery shutdown event posted to AP
- power off system manually within 30 sec -> EC hibernates
3. With system on,
- battfake 2 -> battery shutdown event posted to AP
- do not power off AP
- after 30 sec, EC shuts down AP then hibernates
4. With system on,
- battfake 2 -> battery shutdown event posted to AP
- after 15 sec, apply AC power
- system does NOT shut down
- remove AC power -> battery shutdown event posted to AP
(because battfake 2 is still faking 2% battery left)
- after 30 sec, EC shuts down AP then hibernates
(check to make sure the full 30 sec elapses; the timer
should have been restarted when AC power was removed;
if the EC shuts down the AP immediately this is a
failure indicating the timer is still running from
the first shutdown event)
Change-Id: I1a13765f501d705d3a580b2acbbb173d47e020ff
Signed-off-by: Randall Spangler <rspangler@chromium.org>
Reviewed-on: https://gerrit.chromium.org/gerrit/44413
142 lines
4.1 KiB
C
142 lines
4.1 KiB
C
/* Copyright (c) 2013 The Chromium OS Authors. All rights reserved.
|
|
* Use of this source code is governed by a BSD-style license that can be
|
|
* found in the LICENSE file.
|
|
*/
|
|
|
|
#include "battery_pack.h"
|
|
#include "timer.h"
|
|
|
|
#ifndef __CROS_EC_CHARGE_STATE_H
|
|
#define __CROS_EC_CHARGE_STATE_H
|
|
|
|
/* Update period to prevent charger watchdog timeout */
|
|
#define CHARGER_UPDATE_PERIOD (SECOND * 10)
|
|
|
|
/* Power state task polling period in usec */
|
|
#define POLL_PERIOD_VERY_LONG MINUTE
|
|
#define POLL_PERIOD_LONG (MSEC * 500)
|
|
#define POLL_PERIOD_CHARGE (MSEC * 250)
|
|
#define POLL_PERIOD_SHORT (MSEC * 100)
|
|
#define MIN_SLEEP_USEC (MSEC * 50)
|
|
#define MAX_SLEEP_USEC SECOND
|
|
|
|
/* Power state error flags */
|
|
#define F_CHARGER_INIT (1 << 0) /* Charger initialization */
|
|
#define F_CHARGER_VOLTAGE (1 << 1) /* Charger maximun output voltage */
|
|
#define F_CHARGER_CURRENT (1 << 2) /* Charger maximum output current */
|
|
#define F_BATTERY_VOLTAGE (1 << 3) /* Battery voltage */
|
|
#define F_BATTERY_CURRENT (1 << 4) /* Battery charging current */
|
|
#define F_DESIRED_VOLTAGE (1 << 5) /* Battery desired voltage */
|
|
#define F_DESIRED_CURRENT (1 << 6) /* Battery desired current */
|
|
#define F_BATTERY_TEMPERATURE (1 << 7) /* Battery temperature */
|
|
#define F_BATTERY_MODE (1 << 8) /* Battery mode */
|
|
#define F_BATTERY_CAPACITY (1 << 9) /* Battery capacity */
|
|
#define F_BATTERY_STATE_OF_CHARGE (1 << 10) /* State of charge, percentage */
|
|
|
|
#define F_BATTERY_MASK (F_BATTERY_VOLTAGE | F_BATTERY_CURRENT | \
|
|
F_DESIRED_VOLTAGE | F_DESIRED_CURRENT | \
|
|
F_BATTERY_TEMPERATURE | F_BATTERY_MODE | \
|
|
F_BATTERY_CAPACITY | F_BATTERY_STATE_OF_CHARGE)
|
|
#define F_CHARGER_MASK (F_CHARGER_VOLTAGE | F_CHARGER_CURRENT | \
|
|
F_CHARGER_INIT)
|
|
|
|
/* Power states */
|
|
enum power_state {
|
|
/* Meta-state; unchanged from previous time through task loop */
|
|
PWR_STATE_UNCHANGE = 0,
|
|
/* Initializing charge state machine at boot */
|
|
PWR_STATE_INIT,
|
|
/* Re-initializing charge state machine */
|
|
PWR_STATE_REINIT,
|
|
/* Just transitioned from init to idle */
|
|
PWR_STATE_IDLE0,
|
|
/* Idle; AC present */
|
|
PWR_STATE_IDLE,
|
|
/* Discharging */
|
|
PWR_STATE_DISCHARGE,
|
|
/* Charging */
|
|
PWR_STATE_CHARGE,
|
|
/* Charging, almost fully charged */
|
|
PWR_STATE_CHARGE_NEAR_FULL,
|
|
/* Charging state machine error */
|
|
PWR_STATE_ERROR
|
|
};
|
|
|
|
/* Debugging constants, in the same order as enum power_state. This string
|
|
* table was moved here to sync with enum above.
|
|
*/
|
|
#define POWER_STATE_NAME_TABLE \
|
|
{ \
|
|
"unchange", \
|
|
"init", \
|
|
"reinit", \
|
|
"idle0", \
|
|
"idle", \
|
|
"discharge", \
|
|
"charge", \
|
|
"charge_near_full", \
|
|
"error" \
|
|
}
|
|
/* End of POWER_STATE_NAME_TABLE macro */
|
|
|
|
/* Power state data
|
|
* Status collection of charging state machine.
|
|
*/
|
|
struct power_state_data {
|
|
int ac;
|
|
int charging_voltage;
|
|
int charging_current;
|
|
struct batt_params batt;
|
|
enum power_state state;
|
|
uint32_t error;
|
|
timestamp_t ts;
|
|
};
|
|
|
|
/* State context
|
|
* The shared context for state handler. The context contains current and
|
|
* previous state.
|
|
*/
|
|
struct power_state_context {
|
|
struct power_state_data curr;
|
|
struct power_state_data prev;
|
|
uint32_t *memmap_batt_volt;
|
|
/* TODO(rong): check endianness of EC and memmap*/
|
|
uint32_t *memmap_batt_rate;
|
|
uint32_t *memmap_batt_cap;
|
|
uint8_t *memmap_batt_flags;
|
|
/* Charger and battery pack info */
|
|
const struct charger_info *charger;
|
|
const struct battery_info *battery;
|
|
/* Charging timestamps */
|
|
timestamp_t charger_update_time;
|
|
timestamp_t trickle_charging_time;
|
|
timestamp_t voltage_debounce_time;
|
|
timestamp_t shutdown_warning_time;
|
|
int battery_present;
|
|
};
|
|
|
|
/* Trickle charging state handler.
|
|
* Trickle charging state is sub-state of charging. Normal charging handler
|
|
* can not set battery input current cap to a very low value. This function
|
|
* uses charging voltage to control battery input current.
|
|
*/
|
|
enum power_state trickle_charge(struct power_state_context *ctx);
|
|
|
|
/**
|
|
* Return current charge state.
|
|
*/
|
|
enum power_state charge_get_state(void);
|
|
|
|
/**
|
|
* Return current battery charge percentage.
|
|
*/
|
|
int charge_get_percent(void);
|
|
|
|
/**
|
|
* Return non-zero if discharging and battery so low we should shut down.
|
|
*/
|
|
int charge_want_shutdown(void);
|
|
|
|