mirror of
https://github.com/Telecominfraproject/OpenCellular.git
synced 2025-12-30 10:31:02 +00:00
Before the change was made, the fan control timer keeps running even all of the fans are off. reproduce the problem: 1. fanset 3333 2. fanset 0 fan is disabled but fan control timer keeps running. Signed-off-by: Dino Li <dino.li@ite.com.tw> BRANCH=none BUG=none TEST=1. fanset 3333 2. fanset 0 both fan and timer are off. Change-Id: Id38f3a4c64bbb36e8b32baefd285dbb0bf14e47e Reviewed-on: https://chromium-review.googlesource.com/327870 Commit-Ready: Dino Li <dino.li@ite.com.tw> Tested-by: Dino Li <dino.li@ite.com.tw> Reviewed-by: Vincent Palatin <vpalatin@chromium.org>