Files
OpenCellular/util
Shawn Nematbakhsh 35ea0a968c charge_manager: Bug fixes for power_info host commands
- Correctly identify certain source ports (ex. c-plug to empty a-receptacle)
- Correct ectool power unit print (mV * mA != mW).

BUG=chrome-os-partner:33248
TEST=Manual on Samus. Connect c-plug to empty a-receptacle, run
"ectool --name usbpdpower", verify that port power role is identified
as source. Also, verify that 5000 mV @ 500mA port correctly prints
2500mW total power.
BRANCH=Samus

Signed-off-by: Shawn Nematbakhsh <shawnn@chromium.org>
Change-Id: Icf0850afc570a1056578df9f1a647079a00229b3
Reviewed-on: https://chromium-review.googlesource.com/238235
Reviewed-by: Alec Berg <alecaberg@chromium.org>
Commit-Queue: Alec Berg <alecaberg@chromium.org>
2015-01-07 17:48:09 +00:00
..
2013-12-19 00:12:28 +00:00
2014-12-15 03:51:17 +00:00
2013-07-01 16:14:16 -07:00
2012-11-01 14:09:34 -07:00
2014-10-07 03:37:48 +00:00
2014-02-17 17:35:43 +00:00
2013-07-01 16:14:16 -07:00
2014-01-15 04:52:54 +00:00