Currently charge state machine resets input current limit to default every time AC is connected. Problem is by the time charge state machine gets around to setting input current, it could have already been set by successful PD negotiation, and this ends up overriding that value. This fix has the state machine store desired input current limit, as determined from PD negotation or any other place, and send last desired input current limit on AC connect. BUG=chrome-os-partner:24461 BRANCH=none TEST=load on samus, test toggling between "pd 0 dev 5" and "pd 0 dev 20", and test plugging and unplugging zinger numerous times, and verify charger command always gives the expected input current limit based on PD negotiation. Change-Id: I18d8acc9e2085739e783c9c70c682d46bcce7fdb Signed-off-by: Alec Berg <alecaberg@chromium.org> Reviewed-on: https://chromium-review.googlesource.com/211639 Reviewed-by: Bill Richardson <wfrichar@chromium.org>
79 lines
1.9 KiB
C
79 lines
1.9 KiB
C
/* Copyright (c) 2014 The Chromium OS Authors. All rights reserved.
|
|
* Use of this source code is governed by a BSD-style license that can be
|
|
* found in the LICENSE file.
|
|
*/
|
|
|
|
/* Host command module for PD MCU */
|
|
|
|
#include "charge_state.h"
|
|
#include "common.h"
|
|
#include "console.h"
|
|
#include "host_command.h"
|
|
#include "task.h"
|
|
#include "timer.h"
|
|
#include "util.h"
|
|
|
|
#define CPRINTS(format, args...) cprints(CC_PD_HOST_CMD, format, ## args)
|
|
|
|
#define TASK_EVENT_EXCHANGE_PD_STATUS TASK_EVENT_CUSTOM(1)
|
|
|
|
void host_command_pd_send_status(void)
|
|
{
|
|
task_set_event(TASK_ID_PDCMD, TASK_EVENT_EXCHANGE_PD_STATUS, 0);
|
|
}
|
|
|
|
static void pd_exchange_status(void)
|
|
{
|
|
struct ec_params_pd_status ec_status;
|
|
struct ec_response_pd_status pd_status;
|
|
int rv = 0, tries = 0;
|
|
|
|
/* Send battery state of charge */
|
|
if (charge_get_flags() & CHARGE_FLAG_BATT_RESPONSIVE)
|
|
ec_status.batt_soc = charge_get_percent();
|
|
else
|
|
ec_status.batt_soc = -1;
|
|
|
|
/* Try 3 times to get the PD MCU status. */
|
|
while (tries++ < 3) {
|
|
rv = pd_host_command(EC_CMD_PD_EXCHANGE_STATUS, 0, &ec_status,
|
|
sizeof(struct ec_params_pd_status), &pd_status,
|
|
sizeof(struct ec_response_pd_status));
|
|
if (rv >= 0)
|
|
break;
|
|
task_wait_event(500*MSEC);
|
|
}
|
|
|
|
if (rv < 0) {
|
|
CPRINTS("Host command to PD MCU failed");
|
|
return;
|
|
}
|
|
|
|
/* Set input current limit */
|
|
#ifdef BOARD_SAMUS
|
|
/*
|
|
* TODO(crosbug.com/p/28532): Remove this workaround for Samus p2b
|
|
* boards which cannot correctly limit input current.
|
|
*/
|
|
pd_status.curr_lim_ma = pd_status.curr_lim_ma * 2 / 3;
|
|
#endif
|
|
rv = charge_set_input_current_limit(MAX(pd_status.curr_lim_ma,
|
|
CONFIG_CHARGER_INPUT_CURRENT));
|
|
if (rv < 0)
|
|
CPRINTS("Failed to set input current limit from PD MCU");
|
|
}
|
|
|
|
void pd_command_task(void)
|
|
{
|
|
|
|
while (1) {
|
|
/* Wait for the next command event */
|
|
int evt = task_wait_event(-1);
|
|
|
|
/* Process event to send status to PD */
|
|
if (evt & TASK_EVENT_EXCHANGE_PD_STATUS)
|
|
pd_exchange_status();
|
|
}
|
|
}
|
|
|