Bill Richardson 91a5fa0194 Add more fields and error flags to struct batt_params
This adds two battery parameters that need to be monitored constantly:
remaining_capacity and full_capacity (that one only changes occasionally,
but we have to notify the AP when it does).

It also adds the is_present field to indicate whether the battery is
physically present or not (when we can tell), so we know whether to try to
wake up a deep-discharged battery.

Along with that, we clean up the error flags to provide indication of which
fields were unable to be read, and replace the manual logical-or of all
errors as they were set with a bitmask (BATT_FLAG_BAD_ANY).

No functionality is changed, only new & better information is provided for
use in the upcoming cleanup of the charge state machine.

BUG=chrome-os-partner:20881
BRANCH=ToT
TEST=make buildall -j

All targets build; all tests pass.

Change-Id: I4312c2fdd3cf2dd9570718e90571eff796b269db
Signed-off-by: Bill Richardson <wfrichar@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/191917
Reviewed-by: Randall Spangler <rspangler@chromium.org>