Two accelerometer changes: - Lower accel sampling rate when chipset is off to 10Hz. Increase sampling rate back up to 100Hz when transitioning to S0. - Change the default output data rate of the accelerometers to 100Hz which matches the EC sampling rate when in S0. BUG=none BRANCH=rambi TEST=manual testing. used lidangle command to verify that in S0, EC is sampling at 100Hz, and in S3 or lower it is sampling at 10Hz. Change-Id: Ie4e20f45f9371d674c3325a362d2729c331fac4f Signed-off-by: Alec Berg <alecaberg@chromium.org> Reviewed-on: https://chromium-review.googlesource.com/190032 Reviewed-by: Randall Spangler <rspangler@chromium.org>