This change moves vendor specific temperature ranges to battery pack files or board setup files. And added a host test case to verify that does not change x86 smart battery charging state machine behavior. BUG=chrome-os-partner:21181 BRANCH=None TEST=manual build test: util/ecmakeall.sh hosttests: make hosttests && make runtests Change-Id: I48e76826b5555f64b78e3c063ce5f02416c72aa2 Signed-off-by: Rong Chang <rongchang@chromium.org> Reviewed-on: https://gerrit.chromium.org/gerrit/62978 Reviewed-by: Vic Yang <victoryang@chromium.org>
132 lines
3.0 KiB
C
132 lines
3.0 KiB
C
/* Copyright (c) 2012 The Chromium OS Authors. All rights reserved.
|
|
* Use of this source code is governed by a BSD-style license that can be
|
|
* found in the LICENSE file.
|
|
*
|
|
* Battery pack vendor provided charging profile
|
|
*/
|
|
|
|
#include "battery_pack.h"
|
|
|
|
/*
|
|
* Design capacity
|
|
* Battery capacity = 8200 mAh
|
|
* 1C = 8200 mA
|
|
*/
|
|
#define DESIGN_CAPACITY 8200
|
|
|
|
enum {
|
|
TEMP_RANGE_10,
|
|
TEMP_RANGE_23,
|
|
TEMP_RANGE_35,
|
|
TEMP_RANGE_45,
|
|
TEMP_RANGE_50,
|
|
TEMP_RANGE_MAX
|
|
};
|
|
|
|
enum {
|
|
VOLT_RANGE_7200,
|
|
VOLT_RANGE_8000,
|
|
VOLT_RANGE_8400,
|
|
VOLT_RANGE_MAX
|
|
};
|
|
|
|
/*
|
|
* Vendor provided charging method
|
|
* temp : < 7.2V, 7.2V ~ 8.0V, 8.0V ~ 8.4V
|
|
* - 0 ~ 10 : 0.8A 1.6A 0.8A
|
|
* - 10 ~ 23 : 1.6A 4.0A 1.6A
|
|
* - 23 ~ 35 : 4.0A 4.0A 4.0A
|
|
* - 35 ~ 45 : 1.6A 4.0A 1.6A
|
|
* - 45 ~ 50 : 0.8A 1.6A 0.8A
|
|
*/
|
|
static const int const current_limit[TEMP_RANGE_MAX][VOLT_RANGE_MAX] = {
|
|
{ 800, 1600, 800},
|
|
{1600, 4000, 1600},
|
|
{4000, 4000, 4000},
|
|
{1600, 4000, 1600},
|
|
{ 800, 1600, 800},
|
|
};
|
|
|
|
const struct battery_temperature_ranges bat_temp_ranges = {
|
|
/*
|
|
* Operational temperature range
|
|
* 0 <= T_charge <= 50 deg C
|
|
* -20 <= T_discharge <= 60 deg C
|
|
*/
|
|
.start_charging_min_c = 0,
|
|
.start_charging_max_c = 50,
|
|
.charging_min_c = 0,
|
|
.charging_max_c = 50,
|
|
.discharging_min_c = -20,
|
|
.discharging_max_c = 60,
|
|
};
|
|
|
|
static const struct battery_info info = {
|
|
/*
|
|
* Design voltage
|
|
* max = 8.4V
|
|
* normal = 7.4V
|
|
* min = 6.0V
|
|
*/
|
|
.voltage_max = 8400,
|
|
.voltage_normal = 7400,
|
|
.voltage_min = 6000,
|
|
|
|
/* Pre-charge current: I <= 0.01C */
|
|
.precharge_current = 64, /* mA */
|
|
};
|
|
|
|
static inline void limit_value(int *val, int limit)
|
|
{
|
|
if (*val > limit)
|
|
*val = limit;
|
|
}
|
|
|
|
const struct battery_info *battery_get_info(void)
|
|
{
|
|
return &info;
|
|
}
|
|
|
|
void battery_vendor_params(struct batt_params *batt)
|
|
{
|
|
int *desired_current = &batt->desired_current;
|
|
int temp_range, volt_range;
|
|
int bat_temp_c = DECI_KELVIN_TO_CELSIUS(batt->temperature);
|
|
|
|
/* Limit charging voltage */
|
|
if (batt->desired_voltage > info.voltage_max)
|
|
batt->desired_voltage = info.voltage_max;
|
|
|
|
/* Don't charge if outside of allowable temperature range */
|
|
if (bat_temp_c >= bat_temp_ranges.charging_max_c ||
|
|
bat_temp_c < bat_temp_ranges.charging_min_c) {
|
|
batt->desired_voltage = 0;
|
|
batt->desired_current = 0;
|
|
return;
|
|
}
|
|
|
|
if (bat_temp_c <= 10)
|
|
temp_range = TEMP_RANGE_10;
|
|
else if (bat_temp_c <= 23)
|
|
temp_range = TEMP_RANGE_23;
|
|
else if (bat_temp_c <= 35)
|
|
temp_range = TEMP_RANGE_35;
|
|
else if (bat_temp_c <= 45)
|
|
temp_range = TEMP_RANGE_45;
|
|
else
|
|
temp_range = TEMP_RANGE_50;
|
|
|
|
if (batt->voltage < 7200)
|
|
volt_range = VOLT_RANGE_7200;
|
|
else if (batt->voltage < 8000)
|
|
volt_range = VOLT_RANGE_8000;
|
|
else
|
|
volt_range = VOLT_RANGE_8400;
|
|
|
|
limit_value(desired_current, current_limit[temp_range][volt_range]);
|
|
|
|
/* If battery wants current, give it at least the precharge current */
|
|
if (*desired_current > 0 && *desired_current < info.precharge_current)
|
|
*desired_current = info.precharge_current;
|
|
}
|