Alec Berg 909c3236de zinger: fix down voltage transitions to keep output enabled
Fix bug in which output was disabled on down voltage transitions.
This also changes the behavior of the OVP protection. On down-step
transitions, the OVP threshold is not lowered for a specified amount
of time after the transition to allow the output to dissipate down to
the new voltage. This will still catch a problem if the voltage goes
up instead of down, but avoid OVPing immediately on a normal down
transition.

BUG=chrome-os-partner:30389
BRANCH=none
TEST=Attach to firefly and probe output voltage. Make sure we
transition smoothly going down in voltage.

Change-Id: I7f3a0c17cc8b392a25d24d56d2b7155b806acb64
Signed-off-by: Alec Berg <alecaberg@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/209863