mirror of
https://github.com/Telecominfraproject/oopt-gnpy.git
synced 2025-10-30 01:32:21 +00:00
docs: Improve typography and fix typos in the README
It's quite common to use a ``monospace font`` for referring to identifiers, so let's use that for GitHub's rendering of the main project's README.
This commit is contained in:
151
README.rst
151
README.rst
@@ -62,10 +62,9 @@ How to Install
|
||||
It is recommended that you use a "virtual environment" when installing `gnpy`.
|
||||
Do not install `gnpy` on your system Python.
|
||||
|
||||
We recommend the use of the Anaconda Python distribution
|
||||
(https://www.anaconda.com/download) which comes with many scientific computing
|
||||
We recommend the use of the `Anaconda Python distribution <https://www.anaconda.com/download>`_ which comes with many scientific computing
|
||||
dependencies pre-installed. Anaconda creates a base "virtual environment" for
|
||||
you automatically. You can also create and manage your conda "virtual
|
||||
you automatically. You can also create and manage your ``conda`` "virtual
|
||||
environments" yourself (see:
|
||||
https://conda.io/docs/user-guide/tasks/manage-environments.html)
|
||||
|
||||
@@ -111,7 +110,7 @@ of the `gnpy` repo and install it with:
|
||||
$ python setup.py install # install
|
||||
|
||||
To test that `gnpy` was successfully installed, you can run this command. If it
|
||||
executes without a `ModuleNotFoundError`, you have successfully installed
|
||||
executes without a ``ModuleNotFoundError``, you have successfully installed
|
||||
`gnpy`.
|
||||
|
||||
.. code-block:: shell
|
||||
@@ -193,59 +192,59 @@ information to transmit.)
|
||||
The EDFA equipment library is a list of supported amplifiers. New amplifiers
|
||||
can be added and existing ones removed. Three different noise models are available:
|
||||
|
||||
1. `'type_def': 'variable_gain'` is a simplified model simulating a 2-coil EDFA with internal, input and output VOAs. The NF vs gain response is calculated accordingly based on the input parameters: `nf_min`, `nf_max`, and `gain_flatmax`. It is not a simple interpolation but a 2-stage NF calculation.
|
||||
2. `'type_def': 'fixed_gain'` is a fixed gain model. `NF == Cte == nf0` if `gain_min < gain < gain_flatmax`
|
||||
3. `'type_def': None` is an advanced model. A detailed json configuration file is required (by default `examples/std_medium_gain_advanced_config.json <examples/std_medium_gain_advanced_config.json>`_.) It uses a 3rd order polynomial where NF = f(gain), NF_ripple = f(frequency), gain_ripple = f(frequency), N-array dgt = f(frequency). Compared to the previous models, NF ripple and gain ripple are modelled.
|
||||
1. ``'type_def': 'variable_gain'`` is a simplified model simulating a 2-coil EDFA with internal, input and output VOAs. The NF vs gain response is calculated accordingly based on the input parameters: ``nf_min``, ``nf_max``, and ``gain_flatmax``. It is not a simple interpolation but a 2-stage NF calculation.
|
||||
2. ``'type_def': 'fixed_gain'`` is a fixed gain model. `NF == Cte == nf0` if `gain_min < gain < gain_flatmax`
|
||||
3. ``'type_def': None`` is an advanced model. A detailed JSON configuration file is required (by default `examples/std_medium_gain_advanced_config.json <examples/std_medium_gain_advanced_config.json>`_). It uses a 3rd order polynomial where NF = f(gain), NF_ripple = f(frequency), gain_ripple = f(frequency), N-array dgt = f(frequency). Compared to the previous models, NF ripple and gain ripple are modelled.
|
||||
|
||||
For all amplifier models:
|
||||
|
||||
+----------------------+-----------+-----------------------------------------+
|
||||
+------------------------+-----------+-----------------------------------------+
|
||||
| field | type | description |
|
||||
+======================+===========+=========================================+
|
||||
| `type_variety` | (string) | a unique name to ID the amplifier in the|
|
||||
+========================+===========+=========================================+
|
||||
| ``type_variety`` | (string) | a unique name to ID the amplifier in the|
|
||||
| | | JSON/Excel template topology input file |
|
||||
+----------------------+-----------+-----------------------------------------+
|
||||
| `out_voa_auto` | (boolean) | auto_design feature to optimize the |
|
||||
+------------------------+-----------+-----------------------------------------+
|
||||
| ``out_voa_auto`` | (boolean) | auto_design feature to optimize the |
|
||||
| | | amplifier output VOA. If true, output |
|
||||
| | | VOA is present and will be used to push |
|
||||
| | | amplifier gain to its maximum, within |
|
||||
| | | EOL power margins. |
|
||||
+----------------------+-----------+-----------------------------------------+
|
||||
| `allowed_for_design` | (boolean) | If false, the amplifier will not be |
|
||||
+------------------------+-----------+-----------------------------------------+
|
||||
| ``allowed_for_design`` | (boolean) | If false, the amplifier will not be |
|
||||
| | | picked by auto-design but it can still |
|
||||
| | | be used as a manual input (from JSON or |
|
||||
| | | Excel template topology files.) |
|
||||
+----------------------+-----------+-----------------------------------------+
|
||||
+------------------------+-----------+-----------------------------------------+
|
||||
|
||||
The fiber library currently describes SSMF and NZDF but additional fiber types can be entered by the user following the same model:
|
||||
|
||||
+----------------------+-----------+-----------------------------------------+
|
||||
| field | type | description |
|
||||
+======================+===========+=========================================+
|
||||
| `type_variety` | (string) | a unique name to ID the fiber in the |
|
||||
| ``type_variety`` | (string) | a unique name to ID the fiber in the |
|
||||
| | | JSON or Excel template topology input |
|
||||
| | | file |
|
||||
+----------------------+-----------+-----------------------------------------+
|
||||
| `dispersion` | (number) | (s.m-1.m-1) |
|
||||
| ``dispersion`` | (number) | (s.m-1.m-1) |
|
||||
+----------------------+-----------+-----------------------------------------+
|
||||
| `gamma` | (number) | 2pi.n2/(lambda*Aeff) (w-2.m-1) |
|
||||
| ``gamma`` | (number) | 2pi.n2/(lambda*Aeff) (w-2.m-1) |
|
||||
+----------------------+-----------+-----------------------------------------+
|
||||
|
||||
The transceiver equipment library is a list of supported transceivers. New
|
||||
transceivers can be added and existing ones removed at will by the user. It is
|
||||
used to determine the service list path feasibility when running the
|
||||
path_request_run.py routine.
|
||||
`path_request_run.py routine <examples/path_request_run.py>`_.
|
||||
|
||||
+----------------------+-----------+-----------------------------------------+
|
||||
| field | type | description |
|
||||
+======================+===========+=========================================+
|
||||
| `type_variety` | (string) | a unique name to ID the transceiver in |
|
||||
| ``type_variety`` | (string) | A unique name to ID the transceiver in |
|
||||
| | | the JSON or Excel template topology |
|
||||
| | | input file |
|
||||
+----------------------+-----------+-----------------------------------------+
|
||||
| `frequency` | (number) | Min/max as below. |
|
||||
| ``frequency`` | (number) | Min/max as below. |
|
||||
+----------------------+-----------+-----------------------------------------+
|
||||
| `mode` | (number) | a list of modes supported by the |
|
||||
| ``mode`` | (number) | A list of modes supported by the |
|
||||
| | | transponder. New modes can be added at |
|
||||
| | | will by the user. The modes are specific|
|
||||
| | | to each transponder type_variety. |
|
||||
@@ -257,34 +256,34 @@ The modes are defined as follows:
|
||||
+----------------------+-----------+-----------------------------------------+
|
||||
| field | type | description |
|
||||
+======================+===========+=========================================+
|
||||
| `format` | (string) | a unique name to ID the mode. |
|
||||
| ``format`` | (string) | a unique name to ID the mode |
|
||||
+----------------------+-----------+-----------------------------------------+
|
||||
| `baud_rate` | (number) | in Hz |
|
||||
| ``baud_rate`` | (number) | in Hz |
|
||||
+----------------------+-----------+-----------------------------------------+
|
||||
| `OSNR` | (number) | min required OSNR in 0.1nm (dB) |
|
||||
| ``OSNR`` | (number) | min required OSNR in 0.1nm (dB) |
|
||||
+----------------------+-----------+-----------------------------------------+
|
||||
| `bit_rate` | (number) | in bit/s |
|
||||
| ``bit_rate`` | (number) | in bit/s |
|
||||
+----------------------+-----------+-----------------------------------------+
|
||||
| `roll_off` | (number) | Not used. |
|
||||
| ``roll_off`` | (number) | Not used. |
|
||||
+----------------------+-----------+-----------------------------------------+
|
||||
| `tx_osnr` | (number) | In dB. OSNR out from transponder. |
|
||||
| ``tx_osnr`` | (number) | In dB. OSNR out from transponder. |
|
||||
+----------------------+-----------+-----------------------------------------+
|
||||
| `cost` | (number) | Arbitrary unit |
|
||||
| ``cost`` | (number) | Arbitrary unit |
|
||||
+----------------------+-----------+-----------------------------------------+
|
||||
|
||||
Simulation parameters are defined as follows.
|
||||
|
||||
Auto-design automatically creates EDFA amplifier network elements when they are
|
||||
missing, after a fiber, or between a ROADM and a fiber. This auto-design
|
||||
functionality can be manually and locally deactivated by introducing a `Fused`
|
||||
network element after a `Fiber` or a `Roadm` that doesn't need amplification.
|
||||
functionality can be manually and locally deactivated by introducing a ``Fused``
|
||||
network element after a ``Fiber`` or a ``Roadm`` that doesn't need amplification.
|
||||
The amplifier is chosen in the EDFA list of the equipment library based on
|
||||
gain, power, and NF criteria. Only the EDFA that are marked
|
||||
`'allowed_for_design': true` are considered.
|
||||
``'allowed_for_design': true`` are considered.
|
||||
|
||||
For amplifiers defined in the topology JSON input but whose gain = 0
|
||||
(placeholder), auto-design will set its gain automatically: see `power_mode` in
|
||||
the `Spans` library to find out how the gain is calculated.
|
||||
For amplifiers defined in the topology JSON input but whose ``gain = 0``
|
||||
(placeholder), auto-design will set its gain automatically: see ``power_mode`` in
|
||||
the ``Spans`` library to find out how the gain is calculated.
|
||||
|
||||
Span configuration is performed as follows. It is not a list (which may change
|
||||
in later releases) and the user can only modify the value of existing
|
||||
@@ -293,25 +292,25 @@ parameters:
|
||||
+------------------------+-----------+---------------------------------------------+
|
||||
| field | type | description |
|
||||
+========================+===========+=============================================+
|
||||
| `power_mode` | (boolean) | If false, gain mode. Auto-design sets |
|
||||
| ``power_mode`` | (boolean) | If false, gain mode. Auto-design sets |
|
||||
| | | amplifier gain = preceding span loss, |
|
||||
| | | unless the amplifier exists and its |
|
||||
| | | gain > 0 in the topology input json. |
|
||||
| | | gain > 0 in the topology input JSON. |
|
||||
| | | If true, power mode (recommended for |
|
||||
| | | auto-design and power sweep.) |
|
||||
| | | Auto-design sets amplifier power |
|
||||
| | | according to delta_power_range. If the |
|
||||
| | | amplifier exists with gain > 0 in the |
|
||||
| | | topology json input, then its gain is |
|
||||
| | | topology JSON input, then its gain is |
|
||||
| | | translated into a power target/channel. |
|
||||
| | | Moreover, when performing a power sweep |
|
||||
| | | (see power_range_db in the SI |
|
||||
| | | (see ``power_range_db`` in the SI |
|
||||
| | | configuration library) the power sweep |
|
||||
| | | is performed w/r/t this power target, |
|
||||
| | | regardless of preceding amplifiers |
|
||||
| | | power saturation/limitations. |
|
||||
+------------------------+-----------+---------------------------------------------+
|
||||
| `delta_power_range_db` | (number) | Auto-design only, power-mode |
|
||||
| ``delta_power_range_db`` | (number) | Auto-design only, power-mode |
|
||||
| | | only. Specifies the [min, max, step] |
|
||||
| | | power excursion/span. It is a relative |
|
||||
| | | power excursion w/r/t the |
|
||||
@@ -345,25 +344,24 @@ parameters:
|
||||
| | | a 23 dB span to |
|
||||
| | | power = power_dbm + power_range_db + 1 |
|
||||
+------------------------+-----------+---------------------------------------------+
|
||||
| max_fiber_lineic_loss_ | (number) | Maximum linear fiber loss for Raman |
|
||||
| for_raman` | | amplification use. |
|
||||
| ``max_fiber_lineic_loss_for_raman`` | (number) | Maximum linear fiber loss for Raman |
|
||||
| | | amplification use. |
|
||||
+------------------------+-----------+---------------------------------------------+
|
||||
| `max_length` | (number) | Split fiber lengths > max_length. |
|
||||
| ``max_length`` | (number) | Split fiber lengths > max_length. |
|
||||
| | | Interest to support high level |
|
||||
| | | topologies that do not specify in line |
|
||||
| | | amplification sites. For example the |
|
||||
| | | CORONET_Global_Topology.xls defines |
|
||||
| | | links > 1000km between 2 sites: it |
|
||||
| | | couldn't be simulated if these links |
|
||||
| | | were not splitted in shorter span |
|
||||
| | | lengths. |
|
||||
| | | were not split in shorter span lengths. |
|
||||
+------------------------+-----------+---------------------------------------------+
|
||||
| `length_unit` | "m"/"km" | Unit for max_length. |
|
||||
| ``length_unit`` | "m"/"km" | Unit for ``max_length``. |
|
||||
+------------------------+-----------+---------------------------------------------+
|
||||
| `max_loss` | (number) | Not used in the current code |
|
||||
| ``max_loss`` | (number) | Not used in the current code |
|
||||
| | | implementation. |
|
||||
+------------------------+-----------+---------------------------------------------+
|
||||
| `padding` | (number) | In dB. Min span loss before putting an |
|
||||
| ``padding`` | (number) | In dB. Min span loss before putting an |
|
||||
| | | attenuator before fiber. Attenuator |
|
||||
| | | value |
|
||||
| | | Fiber.att_in = max(0, padding - span_loss). |
|
||||
@@ -378,25 +376,23 @@ parameters:
|
||||
| | | Therefore it is not possible to set |
|
||||
| | | span_loss < padding. |
|
||||
+------------------------+-----------+---------------------------------------------+
|
||||
| `EOL` | (number) | All fiber span loss ageing. The value |
|
||||
| ``EOL`` | (number) | All fiber span loss ageing. The value |
|
||||
| | | is added to the con_out (fiber output |
|
||||
| | | connector). So the design and the path |
|
||||
| | | feasibility are performed with |
|
||||
| | | span_loss + EOL. EOL cannot be set |
|
||||
| | | manually for a given fiber span |
|
||||
| | | (workaround is to specify higher con_out |
|
||||
| | | (workaround is to specify higher ``con_out`` |
|
||||
| | | loss for this fiber). |
|
||||
+------------------------+-----------+---------------------------------------------+
|
||||
| `con_in`, `con_out` | (number) | Default values if Fiber/params/con_in/out |
|
||||
| | | is None in the topology input |
|
||||
| ``con_in``, | (number) | Default values if Fiber/params/con_in/out |
|
||||
| ``con_out`` | | is None in the topology input |
|
||||
| | | description. This default value is |
|
||||
| | | ignored if a Fiber/params/con_in/out |
|
||||
| | | value is input in the topology for a |
|
||||
| | | given Fiber. |
|
||||
+------------------------+-----------+---------------------------------------------+
|
||||
|
||||
**[1]**
|
||||
|
||||
.. code-block:: json
|
||||
|
||||
{
|
||||
@@ -421,28 +417,28 @@ existing parameters:
|
||||
+--------------------------+-----------+---------------------------------------------+
|
||||
| field | type | description |
|
||||
+==========================+===========+=============================================+
|
||||
| `target_pch_out_db` | (number) | Auto-design sets the Roadm egress channel |
|
||||
| ``target_pch_out_db`` | (number) | Auto-design sets the ROADM egress channel |
|
||||
| | | power. This reflects typical control loop |
|
||||
| | | algorithms that adjust Roadm losses to |
|
||||
| | | algorithms that adjust ROADM losses to |
|
||||
| | | equalize channels (eg coming from different |
|
||||
| | | ingress drection or add ports) |
|
||||
| | | Thi is the default value |
|
||||
| | | ingress direction or add ports) |
|
||||
| | | This is the default value |
|
||||
| | | Roadm/params/target_pch_out_db if no value |
|
||||
| | | is given in the Roadm element in the |
|
||||
| | | is given in the ``Roadm`` element in the |
|
||||
| | | topology input description. |
|
||||
| | | This default value is ignored if a |
|
||||
| | | params/target_pch_out_db value is input in |
|
||||
| | | the topology for a given ROADM. |
|
||||
+--------------------------+-----------+---------------------------------------------+
|
||||
| `add_drop_osnr` | (number) | OSNR contribution from the add/drop ports |
|
||||
| ``add_drop_osnr`` | (number) | OSNR contribution from the add/drop ports |
|
||||
+--------------------------+-----------+---------------------------------------------+
|
||||
| `restrictions` | (strings) | Authorized type_variety of amplifier for |
|
||||
| ``restrictions`` | (strings) | Authorized type_variety of amplifier for |
|
||||
| | | booster or preamp. |
|
||||
| | | listed type_variety MUST be defined in the |
|
||||
| | | Listed type_variety MUST be defined in the |
|
||||
| | | Edfa catalog. |
|
||||
+--------------------------+-----------+---------------------------------------------+
|
||||
|
||||
The `SpectralInformation` object can be configured as follows. The user can
|
||||
The ``SpectralInformation`` object can be configured as follows. The user can
|
||||
only modify the value of existing parameters. It defines a spectrum of N
|
||||
identical carriers. While the code libraries allow for different carriers and
|
||||
power levels, the current user parametrization only allows one carrier type and
|
||||
@@ -451,17 +447,18 @@ one power/channel definition.
|
||||
+----------------------+-----------+-------------------------------------------+
|
||||
| field | type | description |
|
||||
+======================+===========+===========================================+
|
||||
| `f_min/max` | (number) | In Hz. Carrier min max excursion |
|
||||
| ``f_min``, | (number) | In Hz. Carrier min max excursion. |
|
||||
| ``f_max`` | | |
|
||||
+----------------------+-----------+-------------------------------------------+
|
||||
| `baud_rate` | (number) | In Hz. Simulated baud rate. |
|
||||
| ``baud_rate`` | (number) | In Hz. Simulated baud rate. |
|
||||
+----------------------+-----------+-------------------------------------------+
|
||||
| `spacing` | (number) | In Hz. Carrier spacing. |
|
||||
| ``spacing`` | (number) | In Hz. Carrier spacing. |
|
||||
+----------------------+-----------+-------------------------------------------+
|
||||
| `roll_off` | (number) | Not used. |
|
||||
| ``roll_off`` | (number) | Not used. |
|
||||
+----------------------+-----------+-------------------------------------------+
|
||||
| `tx_osnr` | (number) | In dB. OSNR out from transponder. |
|
||||
| ``tx_osnr`` | (number) | In dB. OSNR out from transponder. |
|
||||
+----------------------+-----------+-------------------------------------------+
|
||||
| `power_dbm` | (number) | Reference channel power. In gain mode |
|
||||
| ``power_dbm`` | (number) | Reference channel power. In gain mode |
|
||||
| | | (see spans/power_mode = false), all gain |
|
||||
| | | settings are offset w/r/t this reference |
|
||||
| | | power. In power mode, it is the |
|
||||
@@ -474,20 +471,20 @@ one power/channel definition.
|
||||
| | | power sweep is defined (see after) the |
|
||||
| | | design is not repeated. |
|
||||
+----------------------+-----------+-------------------------------------------+
|
||||
| `power_range_db` | (number) | Power sweep excursion around power_dbm. |
|
||||
| ``power_range_db`` | (number) | Power sweep excursion around power_dbm. |
|
||||
| | | It is not the min and max channel power |
|
||||
| | | values! The reference power becomes: |
|
||||
| | | power_range_db + power_dbm. |
|
||||
+----------------------+-----------+-------------------------------------------+
|
||||
| `sys_margins` | (number) | In dB. Added margin on min required |
|
||||
| ``sys_margins`` | (number) | In dB. Added margin on min required |
|
||||
| | | transceiver OSNR. |
|
||||
+----------------------+-----------+-------------------------------------------+
|
||||
|
||||
The `transmission_main_example.py <examples/transmission_main_example.py>`_
|
||||
script propagates a spectrum of channels at 32 Gbaud, 50 GHz spacing and 0
|
||||
dBm/channel. These are not yet parametrized but can be modified directly in the
|
||||
eqpt_config.json (via the SpectralInformation -SI- structure) to accommodate
|
||||
any baud rate, spacing or power demand. The number of channel is computed based on spacing and f_min/max values.
|
||||
``eqpt_config.json`` (via the ``SpectralInformation`` -SI- structure) to accommodate
|
||||
any baud rate, spacing or power demand. The number of channel is computed based on ``spacing`` and ``f_min``, ``f_max`` values.
|
||||
|
||||
Use `examples/path_requests_run.py <examples/path_requests_run.py>`_ to run multiple optimizations as follows:
|
||||
|
||||
@@ -496,7 +493,7 @@ Use `examples/path_requests_run.py <examples/path_requests_run.py>`_ to run mult
|
||||
$ python path_requests_run.py -h
|
||||
Usage: path_requests_run.py [-h] [-v] [-o OUTPUT] [network_filename] [service_filename] [eqpt_filename]
|
||||
|
||||
The `network_filename` and `service_filename` can be an XLS or JSON file. The `eqpt_filename` must be a JSON file.
|
||||
The ``network_filename`` and ``service_filename`` can be an XLS or JSON file. The ``eqpt_filename`` must be a JSON file.
|
||||
|
||||
To see an example of it, run:
|
||||
|
||||
@@ -507,10 +504,10 @@ To see an example of it, run:
|
||||
|
||||
This program requires a list of connections to be estimated and the equipment
|
||||
library. The program computes performances for the list of services (accepts
|
||||
json or excel format) using the same spectrum propagation modules as
|
||||
transmission_main_example.py. Explanation on the Excel template is provided in
|
||||
JSON or Excel format) using the same spectrum propagation modules as
|
||||
``transmission_main_example.py``. Explanation on the Excel template is provided in
|
||||
the `Excel_userguide.rst <Excel_userguide.rst#service-sheet>`_. Template for
|
||||
the json format can be found here: `service-template.json
|
||||
the JSON format can be found here: `service-template.json
|
||||
<service-template.json>`_.
|
||||
|
||||
Contributing
|
||||
|
||||
Reference in New Issue