Commit Graph

7 Commits

Author SHA1 Message Date
Jonas Mårtensson
3a72ce84d0 Reverse order of values in example amplifier config files
As identified in GitHub issue #390, the dgt values (as well as gain and
nf ripple values) in example config json files are listed in order of
increasing wavelength (decreasing frequency) while the code assumes
values listed in the opposite order. This patch reverses the order of
values in affected files so that they are consistent with existing use
in the code.

Also, the f_min value in the Juniper-BoosterHG.json file is updated to
match measurement data so that interpolation is performed correctly.

Change-Id: I97a9d2f9be81380d1658bee5fa1ef4def3e1c537
Signed-off-by: Jonas Mårtensson <jonas.martensson@ri.se>
2021-04-20 21:17:26 +02:00
Jonas Mårtensson
be5519455f Change example file meshTopologyExampleV2.json
Following the change of the corresponding xls file in 60b9256 we should
change also this json file for consistency and to avoid unnecessary
confusion.

Signed-off-by: Jonas Mårtensson <jonas.martensson@ri.se>
Change-Id: Iab12002544ad6b8489d8dfa0511fdce762cc1d7a
2021-04-06 16:06:56 +02:00
Jan Kundrát
f98eb2c10c Merge changes from topic "warning on gain"
* changes:
  Change example file meshTopologyExampleV2.xls
  add warning in case gain over max_flat_gain + extended_gain_range
2021-04-06 10:29:11 +00:00
EstherLerouzic
60b9256f22 Change example file meshTopologyExampleV2.xls
Previous file imposed equipment types inconsistantly with required gain

Signed-off-by: EstherLerouzic <esther.lerouzic@orange.com>
Change-Id: If19c5a0a710edf280fde146bca94c431bb5fe836
2021-04-06 11:53:07 +02:00
EstherLerouzic
093085fba8 adding a roadm sheet to handle per degree info in roadms
This part only targets conversion from an xls input topology file.
In order to define per degree power, the convert function needs to know
the booster final name.
However before this change, the booster name may not be known if there
is no defined amplifier in eqpt sheet at this stage.
In order to solve this ambiguity, the final name are defined in the convert
function provided that the direction is defined in eqpt sheet and
even if the amp type is not defined.

Then the per degrre target power is defined in a new roadm sheet using
the same direction naming as for Eqpt sheet.

Signed-off-by: EstherLerouzic <esther.lerouzic@orange.com>
Change-Id: I8f279aa880aa0a8ceb60e48e43bddb0f6ff06147
2020-11-03 16:44:28 +01:00
Alessio Ferrari
06d59a5834 Introduce polarization mode dispersion (PMD)
Change-Id: I687591df4662884b734ec945e9968713019ea0fc
2020-06-12 09:08:22 +02:00
Jan Kundrát
8eb5980ca9 distribute example data along GNPy
I would like to create a package for distribution to PIP, and this seems
like the path of least resistance.

This is, apparently, the way for shippign arbitrary data with Python
[1]. I've at least tried to make it user-firendly via adding a simple
utility which just prints out whatever that data path is.

[1] https://python-packaging.readthedocs.io/en/latest/non-code-files.html

Change-Id: I220ecad84b1d57d01e3f98f15befc700bd97c0b8
2020-06-08 18:30:36 +02:00