As identified in GitHub issue #390, the dgt values (as well as gain and
nf ripple values) in example config json files are listed in order of
increasing wavelength (decreasing frequency) while the code assumes
values listed in the opposite order. This patch reverses the order of
values in affected files so that they are consistent with existing use
in the code.
Also, the f_min value in the Juniper-BoosterHG.json file is updated to
match measurement data so that interpolation is performed correctly.
Change-Id: I97a9d2f9be81380d1658bee5fa1ef4def3e1c537
Signed-off-by: Jonas Mårtensson <jonas.martensson@ri.se>
Following the change of the corresponding xls file in 60b9256 we should
change also this json file for consistency and to avoid unnecessary
confusion.
Signed-off-by: Jonas Mårtensson <jonas.martensson@ri.se>
Change-Id: Iab12002544ad6b8489d8dfa0511fdce762cc1d7a
This part only targets conversion from an xls input topology file.
In order to define per degree power, the convert function needs to know
the booster final name.
However before this change, the booster name may not be known if there
is no defined amplifier in eqpt sheet at this stage.
In order to solve this ambiguity, the final name are defined in the convert
function provided that the direction is defined in eqpt sheet and
even if the amp type is not defined.
Then the per degrre target power is defined in a new roadm sheet using
the same direction naming as for Eqpt sheet.
Signed-off-by: EstherLerouzic <esther.lerouzic@orange.com>
Change-Id: I8f279aa880aa0a8ceb60e48e43bddb0f6ff06147
I would like to create a package for distribution to PIP, and this seems
like the path of least resistance.
This is, apparently, the way for shippign arbitrary data with Python
[1]. I've at least tried to make it user-firendly via adding a simple
utility which just prints out whatever that data path is.
[1] https://python-packaging.readthedocs.io/en/latest/non-code-files.html
Change-Id: I220ecad84b1d57d01e3f98f15befc700bd97c0b8