mirror of
https://github.com/Telecominfraproject/wlan-lanforge-scripts.git
synced 2025-11-19 03:25:05 +00:00
longevity: Fix parsing MTU/AUTO for PDU size.
Need to convert that to -1 so that LANforge will accept the value. Signed-off-by: Ben Greear <greearb@candelatech.com>
This commit is contained in:
@@ -516,6 +516,7 @@ class L3VariableTime(Realm):
|
|||||||
# stations, so allow skipping it.
|
# stations, so allow skipping it.
|
||||||
# Do clean cx lists so that when we re-apply them we get same endp name
|
# Do clean cx lists so that when we re-apply them we get same endp name
|
||||||
# as we had previously
|
# as we had previously
|
||||||
|
#print("rebuild: Clearing cx profile lists.\n")
|
||||||
self.cx_profile.clean_cx_lists()
|
self.cx_profile.clean_cx_lists()
|
||||||
self.multicast_profile.clean_mc_lists()
|
self.multicast_profile.clean_mc_lists()
|
||||||
|
|
||||||
@@ -538,7 +539,7 @@ class L3VariableTime(Realm):
|
|||||||
self.multicast_profile.create_mc_rx(etype, side_rx=station_profile.station_names)
|
self.multicast_profile.create_mc_rx(etype, side_rx=station_profile.station_names)
|
||||||
else:
|
else:
|
||||||
for _tos in self.tos:
|
for _tos in self.tos:
|
||||||
print("Creating connections for endpoint type: %s TOS: %s"%(etype, _tos))
|
print("Creating connections for endpoint type: %s TOS: %s cx-count: %s"%(etype, _tos, self.cx_profile.get_cx_count()))
|
||||||
self.cx_profile.create(endp_type=etype, side_a=station_profile.station_names, side_b=self.side_b, sleep_time=0, tos=_tos)
|
self.cx_profile.create(endp_type=etype, side_a=station_profile.station_names, side_b=self.side_b, sleep_time=0, tos=_tos)
|
||||||
|
|
||||||
self.cx_count = self.cx_profile.get_cx_count()
|
self.cx_count = self.cx_profile.get_cx_count()
|
||||||
@@ -584,6 +585,12 @@ class L3VariableTime(Realm):
|
|||||||
ul = str(int(int(ul) / self.cx_count))
|
ul = str(int(int(ul) / self.cx_count))
|
||||||
dl = str(int(int(dl) / self.cx_count))
|
dl = str(int(int(dl) / self.cx_count))
|
||||||
|
|
||||||
|
if (ul_pdu == "AUTO" or ul_pdu == "MTU"):
|
||||||
|
ul_pdu = "-1"
|
||||||
|
|
||||||
|
if (dl_pdu == "AUTO" or dl_pdu == "MTU"):
|
||||||
|
dl_pdu = "-1"
|
||||||
|
|
||||||
print("ul: %s dl: %s cx-count: %s rates-are-totals: %s\n"%(ul, dl, self.cx_count, self.rates_are_totals))
|
print("ul: %s dl: %s cx-count: %s rates-are-totals: %s\n"%(ul, dl, self.cx_count, self.rates_are_totals))
|
||||||
|
|
||||||
# Set rate and pdu size config
|
# Set rate and pdu size config
|
||||||
|
|||||||