| #!/usr/bin/env python3
 | |
| """
 | |
| Note: To Run this script gui should be opened with
 | |
| 
 | |
|     path: cd LANforgeGUI_5.4.3 (5.4.3 can be changed with GUI version)
 | |
|           pwd (Output : /home/lanforge/LANforgeGUI_5.4.3)
 | |
|           ./lfclient.bash -cli-socket 3990
 | |
| 
 | |
| This script is used to automate running TR398 tests.  You
 | |
| may need to view a TR398 test configured through the GUI to understand
 | |
| the options and how best to input data.
 | |
|     
 | |
|     ./lf_tr398_test.py --mgr localhost --port 8080 --lf_user lanforge --lf_password lanforge \
 | |
|       --instance_name tr398-instance --config_name test_con \
 | |
|       --upstream 1.2.eth2 \
 | |
|       --test_rig Testbed-01 --pull_report \
 | |
|       --local_lf_report_dir=/tmp/my_report \
 | |
|       --dut5 'TR398-DUT ruckus750-5 4c:b1:cd:18:e8:ec (1)' \
 | |
|       --dut2 'TR398-DUT ruckus750-2 4c:b1:cd:18:e8:e8 (2)' \
 | |
|       --raw_lines_file example-configs/tr398-ferndale-ac-cfg.txt \
 | |
|       --set 'Calibrate Attenuators' 0 \
 | |
|       --set 'Receiver Sensitivity' 0 \
 | |
|       --set 'Maximum Connection' 1 \
 | |
|       --set 'Maximum Throughput' 1 \
 | |
|       --set 'Airtime Fairness' 0 \
 | |
|       --set 'Range Versus Rate' 0 \
 | |
|       --set 'Spatial Consistency' 0 \
 | |
|       --set 'Multiple STAs Performance' 0 \
 | |
|       --set 'Multiple Assoc Stability' 0 \
 | |
|       --set 'Downlink MU-MIMO' 0 \
 | |
|       --set 'AP Coexistence' 0 \
 | |
|       --set 'Long Term Stability' 0
 | |
| 
 | |
| Note:
 | |
|     --raw_line 'line contents' will add any setting to the test config.  This is
 | |
|         useful way to support any options not specifically enabled by the
 | |
|         command options.
 | |
|     --set modifications will be applied after the other config has happened,
 | |
|         so it can be used to override any other config.  Above, we are disabling many
 | |
|         of the subtests, and enablign just Maximum Connection and Maximum Throughput
 | |
|         tests.
 | |
| 
 | |
|     The RSSI values are calibrated, so you will need to run the calibration step and
 | |
|     call with appropriate values for your particular testbed.  This is loaded from
 | |
|     example-configs/tr398-ferndale-ac-cfg.txt in this example.
 | |
|     Contents of that file is a list of raw lines, for instance:
 | |
| 
 | |
| rssi_0_2-0: -26
 | |
| rssi_0_2-1: -26
 | |
| rssi_0_2-2: -26
 | |
| ....
 | |
| 
 | |
| Example of raw text config for TR-398, to show other possible options:
 | |
| 
 | |
| show_events: 1
 | |
| show_log: 0
 | |
| port_sorting: 0
 | |
| kpi_id: TR_398
 | |
| notes0: Standard LANforge TR-398 automation setup, DUT is in large chamber CT840a, LANforge test system is in
 | |
| notes1: smaller CT810a chamber.  CT704b and CT714 4-module attenuators are used.  Directional antennas
 | |
| notes2: mounted on the sides of the DUT chamber are used to communicate to the DUT.   DUT is facing forward at
 | |
| notes3: the zero-rotation angle.
 | |
| bg: 0xE0ECF8
 | |
| show_scan: 1
 | |
| auto_helper: 1
 | |
| skip_2: 0
 | |
| skip_5: 0
 | |
| skip_5b: 1
 | |
| skip_dual: 0
 | |
| skip_tri: 1
 | |
| selected_dut5: TR398-DUT ruckus750-5 4c:b1:cd:18:e8:ec (1)
 | |
| selected_dut2: TR398-DUT ruckus750-2 4c:b1:cd:18:e8:e8 (2)
 | |
| upstream_port: 1.2.2 eth2
 | |
| operator: 
 | |
| mconn: 5
 | |
| band2_freq: 2437
 | |
| band5_freq: 5180
 | |
| tos: 0
 | |
| speed: 65%
 | |
| speed_max_cx_2: 2000000
 | |
| speed_max_cx_5: 8000000
 | |
| max_tput_speed_2: 100000000
 | |
| max_tput_speed_5: 560000000
 | |
| rxsens_deg_rot: 45
 | |
| rxsens_pre_steps: 8
 | |
| stability_udp_dur: 3600
 | |
| stability_iter: 288
 | |
| calibrate_mode: 4
 | |
| calibrate_nss: 1
 | |
| dur120: 120
 | |
| dur180: 180
 | |
| i_5g_80: 195000000
 | |
| i_5g_40: 90000000
 | |
| i_2g_20: 32000000
 | |
| spatial_deg_rot: 30
 | |
| spatial_retry: 0
 | |
| reset_pp: 99
 | |
| rxsens_stop_at_pass: 0
 | |
| auto_coex: 1
 | |
| rvr_adj: 0
 | |
| rssi_2m_2: -20
 | |
| rssi_2m_5: -32
 | |
| extra_dl_path_loss: 3
 | |
| dur60: 60
 | |
| turn_table: TR-398
 | |
| radio-0: 1.1.2 wiphy0
 | |
| radio-1: 1.1.3 wiphy1
 | |
| radio-2: 1.1.4 wiphy2
 | |
| radio-3: 1.1.5 wiphy3
 | |
| radio-4: 1.1.6 wiphy4
 | |
| radio-5: 1.1.7 wiphy5
 | |
| rssi_0_2-0: -26
 | |
| rssi_0_2-1: -26
 | |
| rssi_0_2-2: -26
 | |
| rssi_0_2-3: -26
 | |
| rssi_0_2-4: -27
 | |
| rssi_0_2-5: -27
 | |
| rssi_0_2-6: -27
 | |
| rssi_0_2-7: -27
 | |
| rssi_0_2-8: -25
 | |
| rssi_0_2-9: -25
 | |
| rssi_0_2-10: -25
 | |
| rssi_0_2-11: -25
 | |
| rssi_0_5-0: -38
 | |
| rssi_0_5-1: -38
 | |
| rssi_0_5-2: -38
 | |
| rssi_0_5-3: -38
 | |
| rssi_0_5-4: -38
 | |
| rssi_0_5-5: -38
 | |
| rssi_0_5-6: -38
 | |
| rssi_0_5-7: -38
 | |
| rssi_0_5-8: -47
 | |
| rssi_0_5-9: -47
 | |
| rssi_0_5-10: -47
 | |
| rssi_0_5-11: -47
 | |
| atten-0: 1.1.85.0
 | |
| atten-1: 1.1.85.1
 | |
| atten-2: 1.1.85.2
 | |
| atten-3: 1.1.85.3
 | |
| atten-4: 1.1.1002.0
 | |
| atten-5: 1.1.1002.1
 | |
| atten-8: 1.1.1002.2
 | |
| atten-9: 1.1.1002.3
 | |
| atten_cal: 1
 | |
| rxsens: 0
 | |
| max_cx: 0
 | |
| max_tput: 0
 | |
| atf: 0
 | |
| rvr: 0
 | |
| spatial: 0
 | |
| multi_sta: 0
 | |
| reset: 0
 | |
| mu_mimo: 0
 | |
| stability: 0
 | |
| ap_coex: 0
 | |
| """
 | |
| import sys
 | |
| import os
 | |
| import importlib
 | |
| import argparse
 | |
| import time
 | |
| import json
 | |
| from os import path
 | |
| 
 | |
| if sys.version_info[0] != 3:
 | |
|     print("This script requires Python 3")
 | |
|     exit(1)
 | |
| 
 | |
|  
 | |
| sys.path.append(os.path.join(os.path.abspath(__file__ + "../../../")))
 | |
| 
 | |
| cv_test_manager = importlib.import_module("py-json.cv_test_manager")
 | |
| cvtest = cv_test_manager.cv_test
 | |
| cv_add_base_parser = cv_test_manager.cv_add_base_parser
 | |
| cv_base_adjust_parser = cv_test_manager.cv_base_adjust_parser
 | |
| 
 | |
| 
 | |
| class TR398Test(cvtest):
 | |
|     def __init__(self,
 | |
|                  lf_host="localhost",
 | |
|                  lf_port=8080,
 | |
|                  lf_user="lanforge",
 | |
|                  lf_password="lanforge",
 | |
|                  instance_name="tr398_instance",
 | |
|                  config_name="tr398_config",
 | |
|                  upstream="1.2.eth2",
 | |
|                  test_rig="",
 | |
|                  local_lf_report_dir="",
 | |
|                  pull_report=False,
 | |
|                  load_old_cfg=False,
 | |
|                  raw_lines_file="",
 | |
|                  dut5="",
 | |
|                  dut2="",
 | |
|                  enables=[],
 | |
|                  disables=[],
 | |
|                  raw_lines=[],
 | |
|                  sets=[],
 | |
|                  ):
 | |
|         super().__init__(lfclient_host=lf_host, lfclient_port=lf_port)
 | |
| 
 | |
|         self.lf_host = lf_host
 | |
|         self.lf_port = lf_port
 | |
|         self.lf_user = lf_user
 | |
|         self.lf_password =lf_password
 | |
|         self.instance_name = instance_name
 | |
|         self.config_name = config_name
 | |
|         self.dut5 = dut5
 | |
|         self.dut2 = dut2
 | |
|         self.raw_lines_file = raw_lines_file
 | |
|         self.upstream = upstream
 | |
|         self.pull_report = pull_report
 | |
|         self.load_old_cfg = load_old_cfg
 | |
|         self.test_name = "TR-398"
 | |
|         self.enables = enables
 | |
|         self.disables = disables
 | |
|         self.raw_lines = raw_lines
 | |
|         self.sets = sets
 | |
|         self.local_lf_report_dir = local_lf_report_dir
 | |
|         self.test_rig = test_rig
 | |
| 
 | |
|     def setup(self):
 | |
|         # Nothing to do at this time.
 | |
|         return
 | |
| 
 | |
| 
 | |
|     def run(self):
 | |
|         self.sync_cv()
 | |
|         time.sleep(2)
 | |
|         self.sync_cv()
 | |
| 
 | |
|         blob_test = "%s-"%(self.test_name)
 | |
| 
 | |
|         self.rm_text_blob(self.config_name, blob_test)  # To delete old config with same name
 | |
|         self.show_text_blob(None, None, False)
 | |
| 
 | |
|         # Test related settings
 | |
|         cfg_options = []
 | |
| 
 | |
|         self.apply_cfg_options(cfg_options, self.enables, self.disables, self.raw_lines, self.raw_lines_file)
 | |
| 
 | |
|         # cmd line args take precedence
 | |
|         if self.upstream != "":
 | |
|             cfg_options.append("upstream_port: " + self.upstream)
 | |
|         if self.dut5 != "":
 | |
|             cfg_options.append("selected_dut5: " + self.dut5)
 | |
|         if self.dut2 != "":
 | |
|             cfg_options.append("selected_dut2: " + self.dut2)
 | |
|         if self.test_rig != "":
 | |
|             cfg_options.append("test_rig: " + self.test_rig)
 | |
| 
 | |
|         # We deleted the scenario earlier, now re-build new one line at a time.
 | |
| 
 | |
|         self.build_cfg(self.config_name, blob_test, cfg_options)
 | |
| 
 | |
|         cv_cmds = []
 | |
|         self.create_and_run_test(self.load_old_cfg, self.test_name, self.instance_name,
 | |
|                                  self.config_name, self.sets,
 | |
|                                  self.pull_report, self.lf_host, self.lf_user, self.lf_password,
 | |
|                                  cv_cmds, local_lf_report_dir=self.local_lf_report_dir)
 | |
| 
 | |
|         self.rm_text_blob(self.config_name, blob_test)  # To delete old config with same name
 | |
| 
 | |
| 
 | |
| def main():
 | |
| 
 | |
|     parser = argparse.ArgumentParser(
 | |
|         prog="lf_tr398_test.py",
 | |
|         formatter_class=argparse.RawTextHelpFormatter,
 | |
|         description="""
 | |
|     Open this file in an editor and read the top notes for more details.
 | |
| 
 | |
|     Example:
 | |
| 
 | |
|   ./lf_tr398_test.py --mgr localhost --port 8080 --lf_user lanforge --lf_password lanforge \\
 | |
|       --instance_name tr398-instance --config_name test_con \\
 | |
|       --upstream 1.2.eth2 \\
 | |
|       --test_rig Testbed-01 --pull_report \\
 | |
|       --local_lf_report_dir /tmp/my-report \\
 | |
|       --dut5 'TR398-DUT-r750 ruckus-r750-5g 4c:b1:cd:18:e8:ec (1)' \\
 | |
|       --dut2 'TR398-DUT-r750 ruckus-r750-2g 4c:b1:cd:18:e8:e8 (2)' \\
 | |
|       --raw_lines_file example-configs/tr398-ferndale-ac-cfg.txt \\
 | |
|       --set 'Calibrate Attenuators' 0 \\
 | |
|       --set 'Receiver Sensitivity' 0 \\
 | |
|       --set 'Maximum Connection' 1 \\
 | |
|       --set 'Maximum Throughput' 1 \\
 | |
|       --set 'Airtime Fairness' 0 \\
 | |
|       --set 'Range Versus Rate' 0 \\
 | |
|       --set 'Spatial Consistency' 0 \\
 | |
|       --set 'Multiple STAs Performance' 0 \\
 | |
|       --set 'Multiple Assoc Stability' 0 \\
 | |
|       --set 'Downlink MU-MIMO' 0 \\
 | |
|       --set 'AP Coexistence' 0 \\
 | |
|       --set 'Long Term Stability' 0
 | |
| 
 | |
|    The contents of the 'raw_lines_file' argument can be obtained by manually configuring the
 | |
|    TR398 test in the LANforge GUI, then select 'Show Config' on the Advanced configuration tab,
 | |
|    select that config text, and paste it into a file.  That file is the argument to the
 | |
|    --raw_lines_file argument.
 | |
| 
 | |
|       """
 | |
|                                      )
 | |
| 
 | |
|     cv_add_base_parser(parser)  # see cv_test_manager.py
 | |
| 
 | |
|     parser.add_argument("-u", "--upstream", type=str, default="",
 | |
|                         help="Upstream port for wifi capacity test ex. 1.1.eth2")
 | |
| 
 | |
|     parser.add_argument("--dut2", default="",
 | |
|                         help="Specify 2Ghz DUT used by this test, example: 'TR398-DUT-r750 ruckus-r750-2g 4c:b1:cd:18:e8:e8 (2)'")
 | |
|     parser.add_argument("--dut5", default="",
 | |
|                         help="Specify 5Ghz DUT used by this test, example: 'TR398-DUT-r750 ruckus-r750-5g 4c:b1:cd:18:e8:ec (1)'")
 | |
|     parser.add_argument("--local_lf_report_dir",
 | |
|                         help="--local_lf_report_dir <where to pull reports to>  default '' means put in current working directory",
 | |
|                         default="")
 | |
| 
 | |
|     args = parser.parse_args()
 | |
| 
 | |
|     cv_base_adjust_parser(args)
 | |
| 
 | |
|     CV_Test = TR398Test(lf_host = args.mgr,
 | |
|                         lf_port = args.port,
 | |
|                         lf_user = args.lf_user,
 | |
|                         lf_password = args.lf_password,
 | |
|                         instance_name = args.instance_name,
 | |
|                         config_name = args.config_name,
 | |
|                         upstream = args.upstream,
 | |
|                         pull_report = args.pull_report,
 | |
|                         local_lf_report_dir = args.local_lf_report_dir,
 | |
|                         load_old_cfg = args.load_old_cfg,
 | |
|                         dut2 = args.dut2,
 | |
|                         dut5 = args.dut5,
 | |
|                         raw_lines_file = args.raw_lines_file,
 | |
|                         enables = args.enable,
 | |
|                         disables = args.disable,
 | |
|                         raw_lines = args.raw_line,
 | |
|                         sets = args.set,
 | |
|                         test_rig=args.test_rig
 | |
|                         )
 | |
|     CV_Test.setup()
 | |
|     CV_Test.run()
 | |
| 
 | |
| 
 | |
| if __name__ == "__main__":
 | |
|     main()
 |