kevin: add CHARGER_NARROW_VDC to prevent DC-DC stopping

BD99955 DCDC wiil turn off Vsys voltage under VSYSVAL_THL_SET
or VREF_BAT<VBAT if Charging Voltage set under actual battery
voltage or VSYSVAL_THL_SET.

BUG=chrome-os-partner:53777
BRANCH=none
TEST=boot-up without battery. using zinger or oem supplier
used kevin rev2, rev3

Change-Id: I03c5c52790b2d481be3fa942054516fbefa3ce98
Signed-off-by: Wonjoon Lee <woojoo.lee@samsung.com>
Reviewed-on: https://chromium-review.googlesource.com/348563
Reviewed-by: Shawn N <shawnn@chromium.org>
This commit is contained in:
Wonjoon Lee
2016-06-01 23:39:46 +09:00
committed by chrome-bot
parent 268ca52daa
commit 1361995972

View File

@@ -50,6 +50,7 @@
#define CONFIG_CHARGER
#define CONFIG_CHARGER_BD99955
#define CONFIG_CHARGER_INPUT_CURRENT 512
#define CONFIG_CHARGER_NARROW_VDC
#define CONFIG_CHARGER_V2
#define CONFIG_USB_CHARGER