gma-display_probing: Enable panel power early
Before probing the internal panels EDID, we have to wait for the panel power up delay. To use this time, we enable the panel power before pro- bing any port and can probe external ports during the delay. On a T420 this saves about 5ms without an external display connected and 15ms with. Change-Id: Idce2ebbdb60182c9161e0a92ee4d42ff50c95688 Signed-off-by: Nico Huber <nico.h@gmx.de> Reviewed-on: https://review.coreboot.org/17759 Reviewed-by: Arthur Heymans <arthur@aheymans.xyz>
This commit is contained in:
@@ -128,7 +128,7 @@ is
|
||||
|
||||
if Success then
|
||||
if Port = Internal then
|
||||
Panel.On;
|
||||
Panel.Wait_On;
|
||||
end if;
|
||||
Read_EDID (Raw_EDID, Port, Success);
|
||||
end if;
|
||||
@@ -162,9 +162,6 @@ is
|
||||
pragma Warnings (GNATprove, On, "unused assignment to ""Raw_EDID""");
|
||||
else
|
||||
Success := False;
|
||||
if Port = Internal then
|
||||
Panel.Off;
|
||||
end if;
|
||||
end if;
|
||||
end Probe_Port;
|
||||
|
||||
@@ -173,6 +170,8 @@ is
|
||||
Ports : in Port_List;
|
||||
Max_Pipe : in Pipe_Index := Pipe_Index'Last)
|
||||
is
|
||||
Probe_Internal : Boolean := False;
|
||||
|
||||
Port_Idx : Port_List_Range := Port_List_Range'First;
|
||||
Success : Boolean;
|
||||
begin
|
||||
@@ -181,6 +180,16 @@ is
|
||||
Mode => Invalid_Mode,
|
||||
Framebuffer => Default_FB));
|
||||
|
||||
-- Turn panel on early to probe other ports during the power on delay.
|
||||
for Idx in Port_List_Range loop
|
||||
exit when Ports (Idx) = Disabled;
|
||||
if Ports (Idx) = Internal then
|
||||
Panel.On (Wait => False);
|
||||
Probe_Internal := True;
|
||||
exit;
|
||||
end if;
|
||||
end loop;
|
||||
|
||||
for Pipe in Pipe_Index range
|
||||
Pipe_Index'First .. Pipe_Index'Min (Max_Pipe, Config.Max_Pipe)
|
||||
loop
|
||||
@@ -203,6 +212,11 @@ is
|
||||
|
||||
-- Restore power settings
|
||||
Power_And_Clocks.Power_Set_To (Cur_Configs);
|
||||
|
||||
-- Turn panel power off if probing failed.
|
||||
if Probe_Internal and not Port_Configured (Configs, Internal) then
|
||||
Panel.Off;
|
||||
end if;
|
||||