pd: fix PD power swap when lots of protocol erros
Fix a couple bugs that cause problems when executing a power swap with a poor PD connection. 1) If we are a sink switching to a source and we have turned on vbus and then get an error, then make sure to turn off vbus. 2) If we are a sink switching to a source and we receive a redundant PD_RDY, then ignore it. BUG=chrome-os-partner:32392 BRANCH=samus TEST=load on samus and connect port 0 to 1 creating a poor PD connection with a lot of retries and missed responses. with this change, I swapped power ~20 times with "pd 0 swap power" and each time it was eventually successful. Change-Id: Ib6b97961c7e40186a14ca1d2922b2ce6a6598180 Signed-off-by: Alec Berg <alecaberg@chromium.org> Reviewed-on: https://chromium-review.googlesource.com/241872 Reviewed-by: Vincent Palatin <vpalatin@chromium.org>
This commit is contained in:
committed by
ChromeOS Commit Bot
parent
476e1cedae
commit
83ef084f95
@@ -818,11 +818,13 @@ static void execute_hard_reset(int port)
|
||||
#ifdef CONFIG_USB_PD_DUAL_ROLE
|
||||
/*
|
||||
* If we are swapping to a source and have changed to Rp, restore back
|
||||
* to Rd to match our power_role.
|
||||
* to Rd and turn off vbus to match our power_role.
|
||||
*/
|
||||
if (pd[port].task_state == PD_STATE_SNK_SWAP_STANDBY ||
|
||||
pd[port].task_state == PD_STATE_SNK_SWAP_COMPLETE)
|
||||
pd[port].task_state == PD_STATE_SNK_SWAP_COMPLETE) {
|
||||
pd_set_host_mode(port, 0);
|
||||
pd_power_supply_reset(port);
|
||||
}
|
||||
/*
|
||||
* If we are swapping to a sink and have changed to Rd, change role to
|
||||
* sink to match the CC pull resistor.
|
||||
@@ -1113,6 +1115,8 @@ static void handle_ctrl_request(int port, uint16_t head,
|
||||
} else if (pd[port].task_state == PD_STATE_SNK_DISCOVERY) {
|
||||
/* Don't know what power source is ready. Reset. */
|
||||
set_state(port, PD_STATE_HARD_RESET_SEND);
|
||||
} else if (pd[port].task_state == PD_STATE_SNK_SWAP_STANDBY) {
|
||||
/* Do nothing, assume this is a redundant PD_RDY */
|
||||
} else if (pd[port].power_role == PD_ROLE_SINK) {
|
||||
set_state(port, PD_STATE_SNK_READY);
|
||||
#ifdef CONFIG_CHARGE_MANAGER
|
||||
@@ -2611,6 +2615,7 @@ void pd_task(void)
|
||||
if (res < 0) {
|
||||
/* Restore Rd */
|
||||
pd_set_host_mode(port, 0);
|
||||
pd_power_supply_reset(port);
|
||||
timeout = 10 * MSEC;
|
||||
set_state(port, PD_STATE_SNK_DISCONNECTED);
|
||||
break;
|
||||
|
||||
Reference in New Issue