cr50: allow vendor command to turn update on even in prod images

We want to always be able to update cr50 image to a newer version,
even if the AP is not cooperating.

BRANCH=cr50
BUG=b:35580805
TEST=verified that update of a prod image is possible

Change-Id: I3bbe2c4aca8bf0c3129f4495db0e76405a2ed189
Signed-off-by: Vadim Bendebury <vbendeb@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/511285
Reviewed-by: Nick Sanders <nsanders@chromium.org>
This commit is contained in:
Vadim Bendebury
2017-05-22 14:46:38 -07:00
committed by chrome-bot
parent b3d0d05aa9
commit f2148bc822

View File

@@ -45,8 +45,8 @@ uint32_t usb_extension_route_command(uint16_t command_code,
switch (command_code) {
#ifdef CR50_DEV
case VENDOR_CC_IMMEDIATE_RESET:
case VENDOR_CC_TURN_UPDATE_ON:
#endif /* defined(CR50_DEV) */
case VENDOR_CC_TURN_UPDATE_ON:
case EXTENSION_POST_RESET: /* Always need to be able to reset. */
is_allowed = 1;
break;