Commit Graph

2 Commits

Author SHA1 Message Date
Mary Ruthven
49312e06cd cr50: disable device monitoring when not in ccd
When cr50 is not trying to do ccd, we dont need to monitor the devices.
Disable device state detection interrupts and the AP and EC UARTs.

BUG=none
BRANCH=none
TEST=gru and kevin monitor devices correctly when ccd is enabled, and
dont monitor anything when it is disabled.

Change-Id: Ic3f5974320486ff6dd0147c490a1c294cc2f6a76
Signed-off-by: Mary Ruthven <mruthven@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/356770
Reviewed-by: Aseda Aboagye <aaboagye@chromium.org>
2016-07-12 22:34:56 -07:00
Mary Ruthven
1d7984ad20 cr50: monitor the state of Servo, the EC, and AP
There are a couple of issues that cr50 has when it cannot know the state
of servo, the EC, and the AP. This change adds support so we can detect
when the AP or EC has been powered on and when servo has been connected.
It uses the UART RX signals to monitor the power state of the AP and EC.
The TX signals are used to monitor the state of servo.

BUG=chrome-os-partner:52056,chrome-os-partner:52322
BRANCH=none
TEST=verify device states are correct when the AP and EC are powered on
	or off and when Servo is attached or detached

Change-Id: Id0a2281b65cb367ecc8d0ca2f9a576672318a5fb
Signed-off-by: Mary Ruthven <mruthven@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/344019
2016-05-27 18:08:50 -07:00