Shawn Nematbakhsh 0af6e77a3a charger: Change unlocked battery level ignore conditions
x86 systems will auto-power-on when power is applied to the EC. When
the battery level is critically low, power-on is prevented, except when
the system is unlocked. So, when unlocked, some systems will
auto-power-on regardless of battery level, overcurrent the charger /
battery, and then repeat forever.

Prevent this reboot loop by ignoring auto-power-up when the battery is
critically low, regardless of system unlocked status.

BUG=chrome-os-partner:48339
TEST=Verify power-up is prevented on no-battery chell w/ donette. Then,
run 'powerbtn' on EC console and verify system powers on (and
overcurrents).
BRANCH=None

Change-Id: Ia631b5a8c45b42ec805e4a0c3f827929a0efd236
Signed-off-by: Shawn Nematbakhsh <shawnn@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/319187
Commit-Ready: Shawn N <shawnn@chromium.org>
Tested-by: Shawn N <shawnn@chromium.org>
Reviewed-by: Duncan Laurie <dlaurie@chromium.org>
2016-01-06 18:48:11 -08:00