The temperature of test chamber is 55'C.
Battery temperature is over 60'c when system runs on test chamber.
The system turns off and enter hibernation
because discharging_max_c is set to 60'C.
BUG=b:74414822
BRANCH=none
TEST=Build, flash and check system in test chamber.
Change-Id: Ibfe05f0f31a0ebd9f72926ff7efa8faacca08153
Signed-off-by: YB.Ha <ybha@samsung.com>
Reviewed-on: https://chromium-review.googlesource.com/958802
Commit-Ready: YongBeum Ha <ybha@samsung.com>
Tested-by: YongBeum Ha <ybha@samsung.com>
Reviewed-by: Philip Chen <philipchen@chromium.org>