Vincent Palatin 1a4bf7fdaa zinger: update current and voltage sensing gains
On the P2 boards, the operational amplifier gain for current sensing is
exactly x100 rather than x101.
(non-inverter configuration with R1=1.8kOhm R2=178kOhm)

The voltage gain constant had a typo introducing a 10% error.
the voltage divider is 10k/100k,so it's x11 gain.
ie it should be written (10+100)/10 rather than (10+110).

Signed-off-by: Vincent Palatin <vpalatin@chromium.org>

BRANCH=none
BUG=chrome-os-partner:28331
TEST=make BOARD=zinger
checked manually with a voltmeter and traces.

Change-Id: I8097ab50149fee319efc11ebae75802e8a49a7f8
Reviewed-on: https://chromium-review.googlesource.com/204540
Reviewed-by: Alec Berg <alecaberg@chromium.org>
Commit-Queue: Vincent Palatin <vpalatin@chromium.org>
Tested-by: Vincent Palatin <vpalatin@chromium.org>