- Power up the AP automatically on initial EC power-on. - In S0, wait for 8s power button hold before powering down. - In S3 and lower, power down immediately on power press. - In G3 / S5, power up on lid open. BUG=chrome-os-partner:54582,chrome-os-partner:54511 BRANCH=None TEST=Manual on gru. Verify the following: - AP powers up when battery initially attached. - `reboot` powers up AP after EC reset. - `reboot ap-off` doesn't power up AP. - `apshutdown` + `lidclose` + `lidopen` causes AP power-up. - Holding power for 4s in S0 does not change power state. - Holding power for 8s in S0 causes AP power down. Change-Id: I588056549a972212c28b9aa6a83fe2e0b179baa9 Signed-off-by: Shawn Nematbakhsh <shawnn@chromium.org> Reviewed-on: https://chromium-review.googlesource.com/355650 Commit-Ready: Shawn N <shawnn@chromium.org> Tested-by: Shawn N <shawnn@chromium.org> Reviewed-by: Mary Ruthven <mruthven@chromium.org>