Shawn Nematbakhsh ebcf57035b power: rk3399: Control power state properly on power button / lid toggle
- Power up the AP automatically on initial EC power-on.
- In S0, wait for 8s power button hold before powering down.
- In S3 and lower, power down immediately on power press.
- In G3 / S5, power up on lid open.

BUG=chrome-os-partner:54582,chrome-os-partner:54511
BRANCH=None
TEST=Manual on gru. Verify the following:
- AP powers up when battery initially attached.
- `reboot` powers up AP after EC reset.
- `reboot ap-off` doesn't power up AP.
- `apshutdown` + `lidclose` + `lidopen` causes AP power-up.
- Holding power for 4s in S0 does not change power state.
- Holding power for 8s in S0 causes AP power down.

Change-Id: I588056549a972212c28b9aa6a83fe2e0b179baa9
Signed-off-by: Shawn Nematbakhsh <shawnn@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/355650
Commit-Ready: Shawn N <shawnn@chromium.org>
Tested-by: Shawn N <shawnn@chromium.org>
Reviewed-by: Mary Ruthven <mruthven@chromium.org>
2016-06-24 17:24:08 -07:00
..