Duncan Laurie 2669c65cfb samus: Update thermal table for adjusted Tj_max
Update the thermal table to account for Tj_max changing from 100C to 105C
so the thermal shutdown temperature is 104C instead of 99C.

The warn and high(prochot) values are left the same as we do want to try
and throttle with some room before the critical threshold will pull power.
This is mostly a concern in the factory where they may run without active
cooling during MLB testing.

BUG=chrome-os-partner:35483
BRANCH=samus
TEST=build and boot on samus

Change-Id: Iae55d7ca41f81e6b7250585be374fb8dd1b6533c
Signed-off-by: Duncan Laurie <dlaurie@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/241011
Reviewed-by: Alec Berg <alecaberg@chromium.org>
2015-01-15 18:36:11 +00:00
2015-01-14 21:50:06 +00:00
2015-01-14 21:50:10 +00:00
2014-03-31 22:45:09 +00:00
2012-05-11 09:11:52 -07:00
2015-01-08 23:55:58 +00:00
2014-04-02 19:58:53 +00:00
2014-05-15 05:20:14 +00:00

For an overview of the Embedded Controller firmware, refer to

http://www.chromium.org/chromium-os/2014-firmware-summit
Description
No description provided
Readme 1.4 GiB
Languages
C 64.7%
Lasso 20.7%
ASL 3.6%
JavaScript 3.2%
C# 2.9%