Vincent Palatin 3154abd5c3 ryu: put additional temperature checks for battery charging
Whatever the battery gas gauge returns, ensure we never charge below 0 C
and above 60 C.

Signed-off-by: Vincent Palatin <vpalatin@chromium.org>

BRANCH=smaug
BUG=chrome-os-partner:44820
TEST=charge a Smaug DVT, use a cold spray on the battery and see the
charge stop.

Change-Id: I8670fbe1713b35aa079bebc9c5bb70e9f28cf8ac
Reviewed-on: https://chromium-review.googlesource.com/299945
Trybot-Ready: Vincent Palatin <vpalatin@chromium.org>
Tested-by: Vincent Palatin <vpalatin@chromium.org>
Reviewed-by: Alec Berg <alecaberg@chromium.org>
Commit-Queue: Vincent Palatin <vpalatin@chromium.org>
(cherry picked from commit 1d19259be3b0721667835ce01bfe719fb547785e)
Reviewed-on: https://chromium-review.googlesource.com/299906
Commit-Ready: Vincent Palatin <vpalatin@chromium.org>
2015-09-15 19:17:52 -07:00
2015-05-07 00:00:47 +00:00
2015-08-15 01:32:39 +00:00
2012-05-11 09:11:52 -07:00
2014-04-02 19:58:53 +00:00
2014-05-15 05:20:14 +00:00

For an overview of the Embedded Controller firmware, refer to

http://www.chromium.org/chromium-os/2014-firmware-summit
Description
No description provided