Alec Berg 347c7313a0 pd: ensure power role matches CC pull resistor after hard reset
Make sure the power role and the CC pull resistor match after
receiving hard reset command in the middle of a swap.

BUG=none
BRANCH=samus
TEST=on samus connect left and right ports together with C to C
cable. note that after some collisions and some hard resets, it
eventually stabilizes with one port in SNK_READY, the other in
SRC_READY. without this CL, we get stuck executing a power swap
and our power role and CC resistor get out of sync, requiring
a reboot.

Change-Id: Ia1385eb3a1c503052ad5bfd0d1595ecc096cd5f4
Signed-off-by: Alec Berg <alecaberg@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/239976
Reviewed-by: Vincent Palatin <vpalatin@chromium.org>
Reviewed-by: Todd Broch <tbroch@chromium.org>
2015-01-10 23:44:22 +00:00
2014-03-31 22:45:09 +00:00
2012-05-11 09:11:52 -07:00
2015-01-08 23:55:58 +00:00
2015-01-07 08:45:30 +00:00
2014-04-02 19:58:53 +00:00
2014-05-15 05:20:14 +00:00

For an overview of the Embedded Controller firmware, refer to

http://www.chromium.org/chromium-os/2014-firmware-summit
Description