Bill Richardson 41cde66516 Samus: Handle fan startup in the EC, not the fan controller
The fans on samus have a recommended minimum duty cycle of 20%
while running, but 30% in order to start. We've been using the
EC's built-in fan controller for the start requirement, but it
has a minimum fast-start duty cycle of 50%. It turns out that
that speed is noticeably noisy.

This change handles the startup with logic in the EC instead, so
that the fan only tries to spin at 30% initially (or if it drops
too much below the minimum turning speed).

BUG=chrome-os-partner:33429
BRANCH=ToT,samus
TEST=make buildall -j

Boot the system, let it idle with the browser windows closed, the
browse a bit, then idle. Listen for changes to the fans.

Before, I could hear the fans kick in and out as the AP load
changed. Now it's much quieter.

Change-Id: Id35215520c064eb6843686ec8bb5f3618dac6cf6
Signed-off-by: Bill Richardson <wfrichar@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/227658
Reviewed-by: Randall Spangler <rspangler@chromium.org>
2014-11-06 02:28:22 +00:00
..
2014-10-18 07:38:26 +00:00
2013-12-17 21:27:53 +00:00
2013-04-05 14:28:42 -07:00
2014-06-23 21:48:33 +00:00
2014-02-08 00:14:48 +00:00
2013-10-25 20:12:49 +00:00
2012-10-26 09:49:38 -07:00
2014-10-29 22:23:43 +00:00
2013-06-26 09:08:23 -07:00
2013-10-21 23:59:38 +00:00
2013-06-18 10:31:09 -07:00
2013-10-30 23:10:13 +00:00
2013-08-07 12:43:48 -07:00
2011-12-07 19:10:02 +00:00
2012-10-25 14:12:11 -07:00
2014-03-06 23:14:07 +00:00
2012-10-25 14:12:10 -07:00
2013-10-30 23:10:10 +00:00
2014-09-30 05:42:15 +00:00
2012-10-25 17:03:44 -07:00
2012-08-09 17:40:37 -07:00
2014-07-15 09:07:40 +00:00
2014-06-26 06:48:37 +00:00
2014-10-01 22:42:25 +00:00
2014-01-06 12:40:45 +00:00
2014-03-01 20:15:59 +00:00
2013-11-21 00:09:09 +00:00
2013-10-21 23:59:38 +00:00
2014-07-17 00:40:23 +00:00
2014-06-19 03:28:43 +00:00