Shawn Nematbakhsh 4578166a89 charger: Inhibit power-on until charger is initialized
It's sometimes desirable to boot without a battery, but we may brown out
if we don't have sufficient current. Inhibit AP power-on, even if the system
is unprotected, until our charger and current limit are initialized.

BUG=chrome-os-partner:41258
TEST=Manual on reworked glados with subsequent commit. Remove battery and
attach Zinger. Verify EC powers on and AP doesn't boot. Run `powerbtn`,
verify that AP boots. Remove all power and attach battery, verify that EC
powers on and AP boots.
BRANCH=None

Change-Id: Ifc3d16f8288a035854e9fd05812ce6de33170d6a
Signed-off-by: Shawn Nematbakhsh <shawnn@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/280563
Reviewed-by: Alec Berg <alecaberg@chromium.org>
2015-07-22 22:30:00 +00:00
2015-07-22 06:26:20 +00:00
2015-05-07 00:00:47 +00:00
2015-07-21 01:34:21 +00:00
2015-07-22 22:29:54 +00:00
2012-05-11 09:11:52 -07:00
2014-04-02 19:58:53 +00:00
2014-05-15 05:20:14 +00:00