Alec Berg 4b8be2f778 pd: add hard reset counter to sink hard reset recovery state
The new hard reset recovery state was endlessly sending hard resets.
Added in hard reset counter to cap the number of hard resets for
a sink.

BUG=none
BRANCH=samus
TEST=test with non-PD type-C charger and verify that we only send
two hard resets and set the appropriate input current limit after
the hard resets.

Change-Id: I95a3739be28ad2a5fed245aad021bcd6d51d94b1
Signed-off-by: Alec Berg <alecaberg@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/233754
Reviewed-by: Todd Broch <tbroch@chromium.org>
Reviewed-by: Vincent Palatin <vpalatin@chromium.org>