Vic Yang 4fda01ca91 Plankton: reset USB hub on POR
On power-on reset, the USB hub might get stuck in a locked state due to
a race condition in hardware. Let's reset the hub after 0.5 seconds to
make sure this doesn't happen.

BUG=chrome-os-partner:32163
TEST=Power on the board. Measure the reset signal.
BRANCH=None

Change-Id: I0f89883c5db7c5376f3612da1615ba4f86b5efa6
Signed-off-by: Vic Yang <victoryang@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/219199
Reviewed-by: Alec Berg <alecaberg@chromium.org>