Shawn Nematbakhsh 51227a3cca charge_manager: Assume all chargers are dedicated when in locked RO
In locked RO, the PD state machine is crippled and unable to determine
whether a charger is dual-role capable. In order to charge in locked RO,
assume that all chargers are dedicated.

BUG=None
TEST=Manual on samus_pd. Lock system and reboot to RO. Insert Zinger and
verify that system charges 3A @ 5V.
BRANCH=Samus

Change-Id: I88a3ff248914cd95ebce8e9b91de1001c0f78b55
Signed-off-by: Shawn Nematbakhsh <shawnn@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/250650
Reviewed-by: Alec Berg <alecaberg@chromium.org>
2015-02-18 04:53:38 +00:00