Vic Yang 55e9d8a0c1 ryu: Choose low input voltage whenever possible
To achieve higher power efficiency, we want the input voltage to be as
low as possible. If the PD source advertise several choices over
PD_MAX_POWER_MW, choose the one with the lowest voltage.

BRANCH=Ryu
BUG=None
TEST=Plug in Ryu to Zinger and check that 12V is selected.

Change-Id: Id8c4da65bfd3dfd174e1fd5528af9f7df7da2a74
Signed-off-by: Vic Yang <victoryang@google.com>
Reviewed-on: https://chromium-review.googlesource.com/242670
Reviewed-by: Alec Berg <alecaberg@chromium.org>
Commit-Queue: Vic Yang <victoryang@chromium.org>
Tested-by: Vic Yang <victoryang@chromium.org>
Reviewed-by: Vincent Palatin <vpalatin@chromium.org>