Upon requesting a PD power contract at a new voltage, keep the input
current limit at 500mA until PD_RDY is received.
BUG=b:30744563,chrome-os-partner:59311,chrome-os-partner:44340
BRANCH=ryu, gru, glados
TEST=Manual on kevin, set ilim to 5V through `chglim` console command,
attach zinger. Set ilim to 20V through `chglim`, verify that ilim goes
from 3A to 500mA to 3A.
Signed-off-by: Shawn Nematbakhsh <shawnn@chromium.org>
Change-Id: I452f183cfb958780e336a9f99dc6398356de17a0
Reviewed-on: https://chromium-review.googlesource.com/399918
Commit-Ready: Shawn N <shawnn@chromium.org>
Tested-by: Shawn N <shawnn@chromium.org>
Reviewed-by: Todd Broch <tbroch@chromium.org>
Reviewed-by: Vincent Palatin <vpalatin@chromium.org>