Alec Berg 75f740fa23 glados: isl9237: add HW charge ramping
Add HW charge ramping option and enable on glados.
Modify charge_manager to enable/disable HW charge ramping
when option is defined.

Unfortunately, the isl9237 doesn't have a way to determine
what the input current limit has settled on, so the EC will
always report the max input current for that supplier.

BUG=chrome-os-partner:47335
BRANCH=none
TEST=plug in CDP, SDP, DCP, type-C, and PD charger. Make sure
we ramp to a reasonable value for the correct suppliers.
Make sure we don't ramp for type-C and PD chargers.

Change-Id: Ib541fa0be48d8f4d261c71b853b0ee72b2adbf6b
Signed-off-by: Alec Berg <alecaberg@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/311301
Reviewed-by: Shawn N <shawnn@chromium.org>
2015-11-09 12:49:30 -08:00
2015-05-07 00:00:47 +00:00
2012-05-11 09:11:52 -07:00
2015-11-05 11:10:32 -08:00
2014-04-02 19:58:53 +00:00
2014-05-15 05:20:14 +00:00

For an overview of the Embedded Controller firmware, refer to

http://www.chromium.org/chromium-os/2014-firmware-summit