Nico Huber 7892ff6aa8 gma ironlake: Reorder panel power handling
The panel power sequencer sometimes waits very long without an expli-
cable cause. We can however skip waiting for the panel power sequence
if we're already done with the configuration.

This fixes a sporadic, useless delay of about 130ms on the T420.

Change-Id: I27bf9b8bbae8a7447cde7ea4b88231b1707698b3
Signed-off-by: Nico Huber <nico.h@gmx.de>
Reviewed-on: https://review.coreboot.org/17760
Reviewed-by: Arthur Heymans <arthur@aheymans.xyz>
2017-01-01 17:38:59 +01:00