Experiments showed that some UVP batteries took ~30 seconds to restart its gas gauge IC. This change adds 30 seconds polling check to determine the condition. Signed-off-by: Rong Chang <rongchang@chromium.org> BRANCH=link BUG=chrome-os-partner:13923 BUG=chrome-os-partner:14094 TEST=manual Disconnect battery and plug in charger. The charging LED should turn red after 30 seconds. Change-Id: I425e63c428aeeaf1468bc2f9886457de1145cada Reviewed-on: https://gerrit.chromium.org/gerrit/34886 Reviewed-by: Randall Spangler <rspangler@chromium.org> Commit-Ready: Rong Chang <rongchang@chromium.org> Tested-by: Rong Chang <rongchang@chromium.org>