synced 2026-01-11 02:15:14 +00:00
If charging current is set to 0mA during charging, reference of charge current feedback amp (VREF_CHG) is set to 0V. Hence the DCDC stops switching (because of the EA offset). To eliminate this issue, disable/enable charger depending on the charging current is zero or non-zero respectively. BUG=b:37413065 BRANCH=reef TEST=test 'ectool chargecontrol normal/idle/discharge' are working Change-Id: Id31876afe365a476fb906e059ab519b7a0c9a7c6 Signed-off-by: james_chao <james_chao@asus.com> Signed-off-by: Vijay Hiremath <vijay.p.hiremath@intel.com> Reviewed-on: https://chromium-review.googlesource.com/486101 Reviewed-by: Daisuke Nojiri <dnojiri@chromium.org> (cherry picked from commit 6da9ed8786e90ee91b39934180fe84e01ac30260) Reviewed-on: https://chromium-review.googlesource.com/489812 Commit-Ready: Vijay P Hiremath <vijay.p.hiremath@intel.com> Tested-by: Vijay P Hiremath <vijay.p.hiremath@intel.com>