Files
OpenCellular/chip/lm4
Alec Berg 78992e730b lm4: Fix potential false over-temperature on entry to S0
This fixes a rare problem in which the EC could shutdown due to
a false over-temperature when entering S0 on Haswell architectures.
The fix involves requiring two valid reads of the temperature
sensor (out of the last 4 readings) in order to report it.

BUG=chrome-os-partner:24204
BRANCH=none
TEST=See bug report for a patch that recreates the bug at a
significantly higher rate then it would occur on its own. Using
that patch, I implemented this fix, and made sure that there
were no false over-temperatures reported.

Change-Id: I0454eca1b96fd2fa1833b080026ed8f1caeeddc4
Signed-off-by: Alec Berg <alecaberg@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/177963
Reviewed-by: Randall Spangler <rspangler@chromium.org>
2013-12-09 20:27:33 +00:00
..
2013-10-25 20:12:54 +00:00
2013-11-01 23:08:24 +00:00
2013-11-04 23:15:38 +00:00
2013-10-21 23:59:38 +00:00
2013-11-21 22:21:34 +00:00
2013-10-28 23:38:16 +00:00
2013-11-21 04:30:55 +00:00
2013-10-30 19:45:00 +00:00
2013-10-21 23:59:38 +00:00