Files
OpenCellular/chip
Alec Berg 78992e730b lm4: Fix potential false over-temperature on entry to S0
This fixes a rare problem in which the EC could shutdown due to
a false over-temperature when entering S0 on Haswell architectures.
The fix involves requiring two valid reads of the temperature
sensor (out of the last 4 readings) in order to report it.

BUG=chrome-os-partner:24204
BRANCH=none
TEST=See bug report for a patch that recreates the bug at a
significantly higher rate then it would occur on its own. Using
that patch, I implemented this fix, and made sure that there
were no false over-temperatures reported.

Change-Id: I0454eca1b96fd2fa1833b080026ed8f1caeeddc4
Signed-off-by: Alec Berg <alecaberg@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/177963
Reviewed-by: Randall Spangler <rspangler@chromium.org>
2013-12-09 20:27:33 +00:00
..
2013-12-05 22:30:58 +00:00
2013-12-06 05:21:41 +00:00