Shawn Nematbakhsh a536bdb1cd charger: bd99955: Disable BC1.2 detection
bd99955 enables BC1.2 detection by default and auto-sets current limit
based upon the detection results. This is undesirable because it races
against our external current limit settings (eg. USB-C / PD detection).

BUG=chrome-os-partner:51766
BRANCH=None
TEST=Manual on kevin. Plug zinger 10 times, verify that battery charges
at ~1500mA on each plug, except for cases where Zinger falls into reset
/ OC loop (a separate issue).

Change-Id: I787b2434c30b89fe78bbe50666075c694bf64503
Signed-off-by: Shawn Nematbakhsh <shawnn@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/336970
Commit-Ready: Shawn N <shawnn@chromium.org>
Tested-by: Shawn N <shawnn@chromium.org>
Reviewed-by: Mary Ruthven <mruthven@chromium.org>
2016-04-05 17:48:04 -07:00