Vadim Bendebury ac4c3020de g: tweak cflush() to wait a bit longer
It turns out that even when the UART status register returns TX_IDLE
bit set, the transmitter is still active - probably working out the
stop sequence.

So, resetting immediately after TX_EMPTY is asserted causes the last
character to be corrupted on the receiving side.

This patch adds a wait for the duration of transmitting 10 bits at
115200 baud, which should be plenty. Wait loop in capped in case timer
is not running for any reason.

BRANCH=none
BUG=chrome-os-partner:60321
TEST=added code to print out a string and then call cflush() and reset
     immediately. The last character is not lost any more, the exact
     string is printed.

Change-Id: If386c515d9d9cc63d161fba73e6ed4e70e465136
Signed-off-by: Vadim Bendebury <vbendeb@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/418487
Reviewed-by: Mary Ruthven <mruthven@chromium.org>
2016-12-12 21:03:37 -08:00
2016-11-10 21:28:33 -08:00
2016-12-08 12:32:45 -08:00
2016-09-09 19:20:12 -07:00
2012-05-11 09:11:52 -07:00
2016-10-14 16:05:49 -07:00
2014-04-02 19:58:53 +00:00
2015-12-08 20:05:05 -08:00

For an overview of the Embedded Controller firmware, refer to

http://www.chromium.org/chromium-os/2014-firmware-summit

For instructions on building from source, refer to

http://www.chromium.org/chromium-os/ec-development/getting-started-building-ec-images-quickly
Description
No description provided