Vincent Palatin b170291c36 zinger: do not cut output on up voltage transitions
Update according to the current PD standard, a monotonic transition
seems mandatory in all cases, so keep the voltage output enabled
when increasing the output voltage.

Signed-off-by: Vincent Palatin <vpalatin@chromium.org>

BRANCH=none
BUG=chrome-os-partner:28331
TEST=connect Zinger to Fruitpie and probe the VBUS voltage during a
transition.

Change-Id: I3c728cc0049ca41536efd4f075139626b7d371da
Reviewed-on: https://chromium-review.googlesource.com/202657
Reviewed-by: Alec Berg <alecaberg@chromium.org>
Commit-Queue: Vincent Palatin <vpalatin@chromium.org>
Tested-by: Vincent Palatin <vpalatin@chromium.org>