Vic Yang b7f7cdaa72 ryu: improve inductive charging control
When inductive charging just starts, there might be a blip on
CHARGE_DONE signal and it'd cause our charging control logic to shut
down charging. Fix this by waiting for a second before we start
monitoring CHARGE_DONE.

Also, once we see CHARGE_DONE=1 and disable charging, CHARGE_DONE will
go low. Handle this by ignoring all subsequent CHARGE_DONE change until
the next time the lid is opened.

BRANCH=Ryu
BUG=None
TEST=Pass the updated unit test.
TEST=Charge a base on Ryu P3.

Change-Id: I9d911cd689d8e88ebcd66e6eca7c86dd70704880
Signed-off-by: Vic Yang <victoryang@google.com>
Reviewed-on: https://chromium-review.googlesource.com/243365
Tested-by: Vic Yang <victoryang@chromium.org>
Reviewed-by: Randall Spangler <rspangler@chromium.org>
Reviewed-by: Vincent Palatin <vpalatin@chromium.org>
Commit-Queue: Vic Yang <victoryang@chromium.org>