Alec Berg bd498b593f samus_pd: fix switching spi bus for type-C port 0 and 1
We switched which spi bus we were using for each type-C port EVT,
but missed one place where the busses should have been switched.
Note, this bug wasn't actually causing any problems because
we enable both spi busses at init time and they remain enabled.

BUG=none
BRANCH=none
TEST=load on EVT samus, make sure PD negotiation works on both
ports

Change-Id: I7b4fbee01b58be41521745d7bef6d9357e50be57
Signed-off-by: Alec Berg <alecaberg@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/216606
Reviewed-by: Duncan Laurie <dlaurie@chromium.org>
2014-09-08 23:08:06 +00:00
2014-08-29 03:00:20 +00:00
2014-09-03 22:49:57 +00:00
2014-03-31 22:45:09 +00:00
2012-05-11 09:11:52 -07:00
2014-04-02 19:58:53 +00:00
2014-05-15 05:20:14 +00:00

For an overview of the Embedded Controller firmware, refer to

http://www.chromium.org/chromium-os/2014-firmware-summit