Files
OpenCellular/common
Alec Berg ce6cb6effa pd: implement source recovery time after hard reset
Implemented source recovery time following a hard reset. According
to the spec:

After a hard reset, the source must dissipate output voltage
to vSafe5V. After establishing the safe voltage condition on VBUS,
the power supply shall wait tSrcRecover before powering VBUS to
vSafe5V.

BUG=none
BRANCH=samus
TEST=plug in a type-c to type-a adapter to samus. then issue a hard
reset from the console and verify that it takes nearly a second before
samus re-enables vbus.

Change-Id: Id21eb7cf03759b7ecd64ad11c3c57e66cf35370a
Signed-off-by: Alec Berg <alecaberg@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/222935
Reviewed-by: Vic Yang <victoryang@chromium.org>
Reviewed-by: Vincent Palatin <vpalatin@chromium.org>
2014-10-15 00:09:55 +00:00
..
2014-05-21 20:32:17 +00:00
2013-12-20 05:07:58 +00:00
2014-05-21 20:32:17 +00:00
2014-10-09 20:44:43 +00:00
2014-05-21 20:32:17 +00:00
2014-05-21 20:32:17 +00:00
2014-05-21 20:32:17 +00:00
2014-05-21 20:32:17 +00:00
2014-03-06 21:32:57 +00:00
2014-07-17 00:40:23 +00:00
2013-10-25 20:12:49 +00:00
2014-05-21 20:32:17 +00:00
2014-05-21 20:32:17 +00:00
2013-12-19 00:12:28 +00:00
2014-05-21 20:32:17 +00:00
2014-03-06 21:33:09 +00:00
2014-05-21 20:32:17 +00:00
2014-05-21 20:32:17 +00:00
2014-01-14 09:19:45 +00:00
2014-05-21 20:32:17 +00:00
2014-05-21 20:32:17 +00:00
2014-05-21 20:32:17 +00:00
2013-12-19 00:12:28 +00:00
2014-09-30 05:42:15 +00:00
2014-05-17 20:14:17 +00:00
2013-12-19 00:12:28 +00:00
2014-07-15 09:07:40 +00:00
2014-05-21 20:32:17 +00:00
2014-05-21 20:32:17 +00:00
2014-05-21 20:32:17 +00:00
2014-05-21 20:32:17 +00:00
2014-10-11 07:29:15 +00:00