Alec Berg ce6cb6effa pd: implement source recovery time after hard reset
Implemented source recovery time following a hard reset. According
to the spec:

After a hard reset, the source must dissipate output voltage
to vSafe5V. After establishing the safe voltage condition on VBUS,
the power supply shall wait tSrcRecover before powering VBUS to
vSafe5V.

BUG=none
BRANCH=samus
TEST=plug in a type-c to type-a adapter to samus. then issue a hard
reset from the console and verify that it takes nearly a second before
samus re-enables vbus.

Change-Id: Id21eb7cf03759b7ecd64ad11c3c57e66cf35370a
Signed-off-by: Alec Berg <alecaberg@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/222935
Reviewed-by: Vic Yang <victoryang@chromium.org>
Reviewed-by: Vincent Palatin <vpalatin@chromium.org>
2014-10-15 00:09:55 +00:00
2014-10-11 07:29:15 +00:00
2014-10-11 07:29:15 +00:00
2014-10-09 20:44:43 +00:00
2014-03-31 22:45:09 +00:00
2012-05-11 09:11:52 -07:00
2014-10-02 23:18:25 +00:00
2014-04-02 19:58:53 +00:00
2014-05-15 05:20:14 +00:00

For an overview of the Embedded Controller firmware, refer to

http://www.chromium.org/chromium-os/2014-firmware-summit