Alec Berg cea3f26d5d charge state v2: allow boot without battery when unlocked
Change charge_state_v2 to set the maximum input current limit when
there is no battery present AND the system is not locked. This allows
us to boot without a battery.

Note that using the max input current limit may cause us to overcurrent
our charger, but that's no worse than putting a limit on it and having
the system brownout. Either way you must have a high enough power
charger to boot without a battery.

BUG=chrome-os-partner:35570
BRANCH=samus
TEST=load on samus, remove battery and plug in zinger. check "charger"
has input current limit of 8128mA, and on PD MCU jump back and forth
between RO and RW and make sure system doesn't power off. Note that
without this CL, if you sysjump on the PD MCU it causes input current
limit to reset to 500mA and causes AP to shutoff.

Change-Id: Ie13d97a6b5c0937510cff0cf05fb032898c3b131
Signed-off-by: Alec Berg <alecaberg@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/241762
Reviewed-by: Duncan Laurie <dlaurie@chromium.org>
2015-01-19 22:19:11 +00:00
2015-01-14 21:50:10 +00:00
2014-03-31 22:45:09 +00:00
2012-05-11 09:11:52 -07:00
2015-01-08 23:55:58 +00:00
2014-04-02 19:58:53 +00:00
2014-05-15 05:20:14 +00:00

For an overview of the Embedded Controller firmware, refer to

http://www.chromium.org/chromium-os/2014-firmware-summit