Sam Hurst df80ec22ca pwm: PWM is disabled when duty is set to max value
The CTR was set to 1 less than the max PWM value, so when the DCR
is set to max PWM value, duty goes to zero. The bug is fixed by
setting CTR to PWM max vlaue.

BUG=chrome-os-partner:57052
BRANCH=None
TEST=Manual on terminal.
> pwmduty 1 raw 0
Setting channel 1 to raw 0
  1: disabled
> pwmduty 1 raw 65535
Setting channel 1 to raw 65535
verified that screen didn't blank

Change-Id: I10885d382f1bd252a5e7355da99dc00bd876e29f
Reviewed-on: https://chromium-review.googlesource.com/381632
Commit-Ready: Shawn N <shawnn@chromium.org>
Tested-by: Shawn N <shawnn@chromium.org>
Reviewed-by: Shawn N <shawnn@chromium.org>
2016-09-08 17:57:51 -07:00